Skip to content

Fast quotes for industrial automation spare parts — send your model list today.

SICK

SICK DT35-B15551S04 | 12,000 mm Time-of-Flight Sensor

Tested SICK DT35-B15551S04 time-of-flight sensor with 12,000 mm range, IO-Link V1.1 and IP67 housing — graded and dispatched worldwide.

Part Number DT35-B15551S04

Refurbished / Tested

  • Inspected and condition-graded before shipping
  • Quote with lead time and warranty in 1 business day
  • Global shipping with protective packaging
Specifications

Technical Details

Measuring range 50 mm ... 12,000 mm, 90% remission factor
Resolution 100 µm
Repeatability ≥ 0.5 mm
Measurement accuracy Typ. ± 10 mm
Response time 4.5 ms ... 192.5 ms
Supply voltage DC 12 V ... 30 V
Enclosure rating IP65 / IP67
Dimensions (W x H x D) 32 mm x 58.67 mm x 42.7 mm

Overview

The SICK DT35-B15551S04 is a Switching frequency 166 Hz/50 Hz/25 Hz/12 Hz/3 Hz for industrial control and automation applications.

The SICK DT35-B15551S04 is a time-of-flight distance sensor from the Dx35 family, rated for a measuring range of 50 mm to 12,000 mm at 90% remission. Maintenance teams choose a tested spare for this exact model because it restores laser distance measurement without waiting on factory lead times.

How this sensor Measures Distance

The sensor emits visible red laser light and calculates distance from the time of flight of the reflected beam. Its resolution is 100 µm, repeatability is ≥ 0.5 mm, and measurement accuracy is typically ± 10 mm. Response time is selectable from 4.5 ms to 192.5 ms across five steps, while output time runs from 2 ms to 64 ms. A set-speed function spans Super Fast to Super Slow, so the same unit can trade measurement speed for stability as the application demands.

Figure 1: Front view of the SICK DT35-B15551S04 Switching frequency 166 Hz/50 Hz/25 Hz/12 Hz/3 Hz showing its physical design and enclosure.

Outputs, IO-Link and Electrical Data

Output Q2 is adaptable as a current output, voltage output or digital output. The analog output offers 4 mA to 20 mA into ≤ 450 Ω or 0 V to 10 V into ≥ 50,000 Ω at 12-bit resolution. Digital output type is push-pull PNP/NPN, with maximum output current IA ≤ 100 mA. IO-Link V1.1 with COM2 at 38.4 kBaud carries process data, parameterization, diagnosis and data storage. Supply voltage is DC 12 V to 30 V, power consumption is ≤ 1.7 W, and initialization takes ≤ 500 ms.

Figure 2: Technical layout and connection details for the SICK DT35-B15551S04 Switching frequency 166 Hz/50 Hz/25 Hz/12 Hz/3 Hz.

Tested-Parts Advantage and Sourcing Notes

Every this sensor we supply is inspected and functionally checked before dispatch, and its condition is clearly graded so you know what arrives. That matters when a sensor on a running line fails and the alternative is an open-ended factory lead time. The housing measures 32 mm x 58.67 mm x 42.7 mm and weighs 65 g, with an enclosure rating of IP65 or IP67 and protection class III. Operating ambient temperature spans –30 °C to +55 °C at Uv ≤ 24 V, and the unit meets EN 60068-2-6, EN 60068-2-64 and EN 60068-2-27 for vibration and shock. Laser class 1 per IEC 60825-1:2014 and EN 60825-1:2014 applies, and average laser service life is 100,000 h at 25 °C. Confirm the exact revision and connector type against your existing installation before ordering.

Common questions

Frequently Asked Questions

What is the part number of this product?

The part number is DT35-B15551S04, manufactured by SICK. The marking on the unit itself should match this number — confirm the revision code on the nameplate when comparing with your installed hardware.

What condition is this DT35-B15551S04 shipped in?

This unit is offered as refurbished / tested stock: inspected and condition-graded before shipping, packed in protective anti-static material. The current availability and condition grade are confirmed in your quote.

How do I get a quote for DT35-B15551S04?

Use the Request a Quote button on this page or send us your model list — pricing, lead time and warranty terms are returned within one business day. A service manual download is available above when applicable.

What are the key specifications of DT35-B15551S04?

DT35-B15551S04 is specified as Measuring range: 50 mm ... 12,000 mm, 90% remission factor; Resolution: 100 µm; Repeatability: ≥ 0.5 mm. The full set of verified technical parameters is listed in the specification table above.

Need this part?

Get pricing, condition and lead time in one business day.