The Siemens 3RW4457-6BC44 is a Soft starter Values at 400 V for industrial control and automation applications.
The Siemens 3RW4457-6BC44 is a SIRIUS soft starter rated 880 A at 400 V and 40 °C in standard circuit, delivering 500 kW. Maintenance teams choose a tested spare for this exact model to restore motor starting quickly, with units inspected and functionally checked before dispatch.
Product Overview and Series Context
This soft starter belongs to the SIRIUS family and handles three-phase motor starting with integrated bypass contact system and thyristors. It supports inside-delta circuit configuration, raising the 400 V rating to 1524 A and 900 kW at 40 °C. The operating voltage range is 200–460 V AC, and control supply is 230 V AC at 50 or 60 Hz. Screw terminals serve auxiliary and control circuits, while the main current circuit uses busbar connection. The unit measures 510 mm wide, 640 mm high and 290 mm deep, with screw fixing and a rotatable mounting position. Front protection is IP00, so it must sit inside an enclosure.

Tested-Parts Advantage for Maintenance Engineers
A failed soft starter stops the driven motor immediately, and production loss grows with every hour. Factory lead times for large-frame starters can be long, so a tested spare often restores service faster. SpareTechHub grades each unit and performs functional checks before dispatch, covering the integrated bypass, thyristor firing and control inputs. Because this unit is a phased-out product with the SIRIUS 3RW5 as successor, sourcing a verified original unit keeps existing panels unchanged. Maintenance engineers avoid re-engineering the cabinet, re-terminating busbars or updating drawings. Every unit is condition clearly graded, so you know what arrives before installation begins.

Maintenance and Reliability Notes
Schedule periodic inspection of busbar connections and screw terminals, since loose joints raise resistance and heat. Verify the integrated bypass contact system operates cleanly and check thyristor cooling paths for dust buildup. The ambient operating limit is 60 °C, but derating begins above 40 °C; keep panel ventilation adequate. The starter accepts a thermistor motor protection input and provides external reset, which simplifies fault recovery. Mounting allows ±90° rotation on a vertical surface and ±22.5° tilt front to back, with required clearances of 100 mm upward, 5 mm at the side and 75 mm downward for side-by-side mounting. For safety, isolate all power feeds and follow the manufacturer’s manual before any service work.