IV3-G500CA | Keyence Sensor Head

Compact model sensor head for IV3-G120 amplifier, standard field of view, color type.

Part Number IV3-G500CA

  • Inspected and condition-graded before shipping
  • Quote with lead time and warranty in 1 business day
  • Global shipping with protective packaging
Specifications

Technical Details

Type Compact model sensor head, standard view
Installed distance 50 mm or more
Field of view Installation distance 50 mm: 22 (H) x 16 (V) mm to installation distance 3000 mm: 1184 (H) x 888 (V) mm (typical example)
Image receiving element 1/2.9 inch color CMOS, 1280 (H) x 960 (V) pixels
Focus adjustment Auto
Exposure time 12 us to 9 ms
Illumination White LED
Lighting method Pulse / continuous lighting switchable
Built-in ports None (connects to IV3-G120 amplifier via dedicated cable)
Protocols None
Communication expansion Via IV3-G120 amplifier
Supply voltage Supplied by connected amplifier
Power consumption Not available
Output type Not available (outputs via amplifier)
Operating temperature 0 to +50°C (no freezing)
Relative humidity 35 to 85% RH (no condensation)
Protection rating IP67 (except when polarizing filter OP-88642/OP-88643/OP-88646/OP-88647 is mounted)
Vibration resistance 10 to 55 Hz, double amplitude 1.5 mm, 2 hours in each of X/Y/Z directions (except when dome attachment IV2-GD05/IV2-GD10 is mounted)
Shock resistance 500 m/s^2, 3 times in each of 6 directions (except when dome attachment IV2-GD05/IV2-GD10 is mounted)
Dimensions (H×W×D) Not available
Material Main unit case: Zinc die-casting. Front cover: Acrylic. Operation indicator cover: TPU.
Weight Approx. 75 g (without AI lighting unit), approx. 225 g (with AI lighting unit)
Active; official Keyence production status confirmed via product/spec page (Last verified 2026-09)

Overview

Model: IV3-G500CA
Brand: Keyence
Series: IV3 Series

Compact model sensor head for IV3-G120 amplifier, standard field of view, color type.

Hardware

Type: Compact model sensor head, standard view
Installed distance: 50 mm or more
Field of view: Installation distance 50 mm: 22 (H) x 16 (V) mm to installation distance 3000 mm: 1184 (H) x 888 (V) mm (typical example)
Image receiving element: 1/2.9 inch color CMOS, 1280 (H) x 960 (V) pixels
Focus adjustment: Auto
Exposure time: 12 us to 9 ms
Illumination: White LED
Lighting method: Pulse / continuous lighting switchable

Communication

Built-in ports: None (connects to IV3-G120 amplifier via dedicated cable)
Protocols: None
Communication expansion: Via IV3-G120 amplifier

Electrical

Supply voltage: Supplied by connected amplifier
Power consumption: Not available
Output type: Not available (outputs via amplifier)

Environmental

Operating temperature: 0 to +50°C (no freezing)
Relative humidity: 35 to 85% RH (no condensation)
Protection rating: IP67 (except when polarizing filter OP-88642/OP-88643/OP-88646/OP-88647 is mounted)
Vibration resistance: 10 to 55 Hz, double amplitude 1.5 mm, 2 hours in each of X/Y/Z directions (except when dome attachment IV2-GD05/IV2-GD10 is mounted)
Shock resistance: 500 m/s^2, 3 times in each of 6 directions (except when dome attachment IV2-GD05/IV2-GD10 is mounted)

Physical

Dimensions (H×W×D): Not available
Material: Main unit case: Zinc die-casting. Front cover: Acrylic. Operation indicator cover: TPU.
Weight: Approx. 75 g (without AI lighting unit), approx. 225 g (with AI lighting unit)

Lifecycle

Active; official Keyence production status confirmed via product/spec page (Last verified: 2026-09)

Common questions

Frequently Asked Questions

What is the part number of this product?

The part number is IV3-G500CA, manufactured by Keyence. The marking on the unit itself should match this number — confirm the revision code on the nameplate when comparing with your installed hardware.

How do I get a quote for IV3-G500CA?

Use the Request a Quote button on this page or send us your model list — pricing, lead time and warranty terms are returned within one business day. A service manual download is available above when applicable.

What are the key specifications of IV3-G500CA?

IV3-G500CA is specified as Type: Compact model sensor head, standard view; Installed distance: 50 mm or more; Field of view: Installation distance 50 mm: 22 (H) x 16 (V) mm to installation distance 3000 mm: 1184 (H) x 888 (V) mm (typical example). The full set of verified technical parameters is listed in the specification table above.

Need this part?

Get pricing, condition and lead time in one business day.