Model: LR-ZB240CB
Brand: Keyence
Series: LR-Z series
Self-contained CMOS laser photoelectric sensor, m18 threaded mount, Bipolar (NPN+PNP) output, m12 connector, 4-pin.
Hardware
Sensor type: Self-contained CMOS laser photoelectric sensor (U.C.D. distance/contrast detection)
Shape: M18 threaded mount
Cable connection: M12 connector, 4-pin
Detecting distance: 25 to 240 mm
Standard detectable deviation: 25 to 170 mm: 9 mm; 170 to 240 mm: 25 mm
Display resolution: 1 to 3 (1 to 3 mm)
Spot diameter: Approx. 2.4 x 1.2 mm at 240 mm
Light source: Red laser, wavelength 660 nm
Laser class: Class 1 (IEC60825-1; FDA CDRH Part1040.10)
Response time: 1.5 ms / 10 ms / 50 ms selectable
Timer: OFF / ON-delay / OFF-delay / one-shot
Communication
Built-in ports: None
Protocols: IO-Link v1.1 / COM2 (38.4 kbps) on CB/C3P connector-type models
Communication expansion: None
Electrical
Supply voltage: 10 to 30 VDC, including 10% ripple (P-P), Class 2 or LPS
Power consumption: 450 mW or less (18 mA or less at 24 V; 34 mA or less at 12 V)
Output type: Bipolar (NPN+PNP) open collector, applied voltage 30 VDC or less, control current 100 mA or less, residual voltage 1.2 V or less at 10 mA or less
Output operation: Light-ON / Dark-ON selectable
Environmental
Operating temperature: -10 to +50 °C (No freezing)
Storage temperature: -25 to +75 °C (No freezing)
Relative humidity: 35 to 85 % RH (No condensation)
Protection rating: IP68 (IEC60529), IP69K (DIN40050-9), NEMA 4X / 6P / 13
Physical
Dimensions (H×W×D): Not available
Weight: Approx. 55 g (connector type)
Lifecycle
Active; official Keyence production status confirmed via product/spec page (Last verified: 2026-09)