Skip to content

Fast quotes for industrial automation spare parts — send your model list today.

Keyence

FS-N44N | Keyence Amplifier Npn Output Expansion Unit

Digital fiber optic sensor amplifier, NPN output, Expansion unit (dual output) with OLED display.

Part Number FS-N44N

  • Inspected and condition-graded before shipping
  • Quote with lead time and warranty in 1 business day
  • Global shipping with protective packaging
Specifications

Technical Details

Type Cable type
Output NPN
Main/expansion Expansion unit (dual output)
Control outputs 2
External inputs 1
Response time 23 µs (S-HSPD) / 50 µs (HSPD) / 250 µs (FINE) / 500 µs (TURBO) / 1 ms (SUPER) / 4 ms (ULTRA) / 16 ms (MEGA) / 64 ms (TERA)
Light source Red four-element LED, wavelength 660 nm
Unit expansion Up to 16 units (17 total incl. main; dual-output counts as 2)
Control output Open-collector, 30 V max, 100 mA max per output, residual voltage 1.4 V at 10 mA; 2 V at 10-100 mA
External input Input time 2 ms (ON) / 20 ms (OFF) or longer
Built-in ports None
Protocols None
Communication expansion None
Supply voltage 10 to 30 VDC (including 10% ripple P-P or less), class 2 or LPS
Power consumption 870 mW or less (34 mA at 24 V; ECO ON 800 mW; ECO FULL 710 mW)
Operating temperature -20 to +55 °C (no freezing; derates with expansion)
Storage temperature Not available
Relative humidity Not available
Protection rating Not available
Dimensions (H×W×D) Not available
Weight Approx. 73 g
Active; official Keyence production status confirmed via product/spec page (Last verified 2026-09)

Overview

Model: FS-N44N
Brand: Keyence
Series: FS-N40

Digital fiber optic sensor amplifier, NPN output, Expansion unit (dual output) with OLED display.

Hardware

Type: Cable type
Output: NPN
Main/expansion: Expansion unit (dual output)
Control outputs: 2
External inputs: 1
Response time: 23 µs (S-HSPD) / 50 µs (HSPD) / 250 µs (FINE) / 500 µs (TURBO) / 1 ms (SUPER) / 4 ms (ULTRA) / 16 ms (MEGA) / 64 ms (TERA)
Light source: Red four-element LED, wavelength 660 nm
Unit expansion: Up to 16 units (17 total incl. main; dual-output counts as 2)

I/O Specifications

Control output: Open-collector, 30 V max, 100 mA max per output, residual voltage 1.4 V at 10 mA; 2 V at 10-100 mA
External input: Input time 2 ms (ON) / 20 ms (OFF) or longer

Communication

Built-in ports: None
Protocols: None
Communication expansion: None

Electrical

Supply voltage: 10 to 30 VDC (including 10% ripple P-P or less), class 2 or LPS
Power consumption: 870 mW or less (34 mA at 24 V; ECO ON 800 mW; ECO FULL 710 mW)

Environmental

Operating temperature: -20 to +55 °C (no freezing; derates with expansion)
Storage temperature: Not available
Relative humidity: Not available
Protection rating: Not available

Physical

Dimensions (H×W×D): Not available
Weight: Approx. 73 g

Lifecycle

Active; official Keyence production status confirmed via product/spec page (Last verified: 2026-09)

Common questions

Frequently Asked Questions

What is the part number of this product?

The part number is FS-N44N, manufactured by Keyence. The marking on the unit itself should match this number — confirm the revision code on the nameplate when comparing with your installed hardware.

How do I get a quote for FS-N44N?

Use the Request a Quote button on this page or send us your model list — pricing, lead time and warranty terms are returned within one business day. A service manual download is available above when applicable.

What are the key specifications of FS-N44N?

FS-N44N is specified as Type: Cable type; Output: NPN; Main/expansion: Expansion unit (dual output). The full set of verified technical parameters is listed in the specification table above.

Need this part?

Get pricing, condition and lead time in one business day.