Skip to content

Fast quotes for industrial automation spare parts — send your model list today.

Keyence

IG-010 | Keyence IG Series Sensor Head

Sensor head for the IG series multi-purpose CCD laser micrometer (thru-beam CCD method).

Part Number IG-010

  • Inspected and condition-graded before shipping
  • Quote with lead time and warranty in 1 business day
  • Global shipping with protective packaging
Specifications

Technical Details

Operation principle CCD method
Light source wavelength 660 nm (visible light semiconductor laser)
Laser class Class 1 (FDA / IEC / JIS)
Mounting distance 0 to 1,000 mm
Measurement range 10 mm
Sampling cycle 980 µs (490 µs when averaging is set to [hsp])
Minimum detectable object 0.1 mm dia. (high sensitivity mode, at 100 mm setting distance)
Repeatability 5 µm (at 100 mm), 10 µm (at 500 mm), 80 µm (at 1,000 mm)
Linearity +/-0.28 % of F.S. (+/-28 µm)
Temperature characteristics +/-0.03 % of F.S./°C (+/-3 µm/°C)
Supplied accessories Transmitter x 1, Receiver x 1, sensor head cables (2 m) x 2
Built-in ports Sensor head cables (2 m)
Protocols Not available
Communication expansion None (sensor head; connects to IG series amplifier unit)
Supply voltage Not available (powered by connected IG series amplifier unit)
Power consumption Not available
Operating temperature -10 to +45 °C (No freezing)
Storage temperature Not available
Relative humidity 35 to 85 % RH (No condensation)
Protection rating IP67
Ambient light Incandescent lamp 5,000 lux, sunlight 5,000 lux
Vibration resistance 10 to 55 Hz, double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z axes
Dimensions (H×W×D) Not available
Weight Approx. 380 g (including supplied items)
Current IG series product; official product page active as of 2026-09 (Last verified 2026-09)

Overview

Model: IG-010
Brand: Keyence
Series: IG series

Sensor head for the IG series multi-purpose CCD laser micrometer (thru-beam CCD method).

Hardware

Operation principle: CCD method
Light source wavelength: 660 nm (visible light semiconductor laser)
Laser class: Class 1 (FDA / IEC / JIS)
Mounting distance: 0 to 1,000 mm
Measurement range: 10 mm
Sampling cycle: 980 µs (490 µs when averaging is set to [hsp])
Minimum detectable object: 0.1 mm dia. (high sensitivity mode, at 100 mm setting distance)
Repeatability: 5 µm (at 100 mm), 10 µm (at 500 mm), 80 µm (at 1,000 mm)
Linearity: +/-0.28 % of F.S. (+/-28 µm)
Temperature characteristics: +/-0.03 % of F.S./°C (+/-3 µm/°C)
Supplied accessories: Transmitter x 1, Receiver x 1, sensor head cables (2 m) x 2

Communication

Built-in ports: Sensor head cables (2 m)
Protocols: Not available
Communication expansion: None (sensor head; connects to IG series amplifier unit)

Electrical

Supply voltage: Not available (powered by connected IG series amplifier unit)
Power consumption: Not available

Environmental

Operating temperature: -10 to +45 °C (No freezing)
Storage temperature: Not available
Relative humidity: 35 to 85 % RH (No condensation)
Protection rating: IP67
Ambient light: Incandescent lamp 5,000 lux, sunlight 5,000 lux
Vibration resistance: 10 to 55 Hz, double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z axes

Physical

Dimensions (H×W×D): Not available
Weight: Approx. 380 g (including supplied items)

Lifecycle

Current IG series product; official product page active as of 2026-09 (Last verified: 2026-09)

Common questions

Frequently Asked Questions

What is the part number of this product?

The part number is IG-010, manufactured by Keyence. The marking on the unit itself should match this number — confirm the revision code on the nameplate when comparing with your installed hardware.

How do I get a quote for IG-010?

Use the Request a Quote button on this page or send us your model list — pricing, lead time and warranty terms are returned within one business day. A service manual download is available above when applicable.

What are the key specifications of IG-010?

IG-010 is specified as Operation principle: CCD method; Light source wavelength: 660 nm (visible light semiconductor laser); Laser class: Class 1 (FDA / IEC / JIS). The full set of verified technical parameters is listed in the specification table above.

Need this part?