DT50-N1124 | SICK Rugged metal zinc die-cast housing

Direct diffuse distance measurement up to 10 m on natural objects (no reflector required) Rugged metal zinc die-cast housing (ZNAL4CU1) engineered for heavy-duty industrial automation High-resolution distance measurement with LC display and intuitive menu navigation buttons Optical time-of-flight technology (HDDM™) ensuring high repeatability and ambient light stability Factory-integrated internal heater for cold-storage and deep-freeze operation down to -40 °C

Part Number DT50-N1124

  • Inspected and condition-graded before shipping
  • Quote with lead time and warranty in 1 business day
  • Global shipping with protective packaging
Specifications

Technical Details

Part Number 1047617
Product Sub-Series / Family Dx50 DT50 Heated
Measurement Principle HDDM™ (High Definition Distance Measurement) Optical Time-of-Flight
Measuring / Protective Range 200 mm ... 10,000 mm (90% remission), 200 mm ... 6,500 mm (18%), 200 mm ... 4,000 mm (6%)
Light Source Visible red laser diode (wavelength 658 nm; Class 1 eye-safe per IEC 60825-1:2014; pulse peak 120 mW, pulse duration 2.5 ns)
Laser Class Class 1 (IEC 60825-1:2014, EN 60825-1:2014, Eye-safe)
Response Time Fast: 20 ms / Slow: 30 ms (Averaging setting)
Repeatability ≥ 2.5 mm
Measurement Accuracy Typ. ± 10 mm
Output & Communication Interface Digital Output: 1x NPN (≤ 100 mA); Analog Output: 1x Voltage output (0 V ... 10 V, ≥ 5 kΩ, 16-bit); Multifunctional input (MF)
Supply Voltage DC 24 V (18 V ... 30 V; VS > 15 V required for internal heating element; Reverse-polarity protected)
Power Consumption ≤ 28 W (Heater active, without external load)
Electrical Connection Male connector M12, 8-pin
Ambient Temperature, Operation -40 °C ... +65 °C (Integrated heating; -40 °C ... +80 °C with 2 cooling plates; -40 °C ... +140 °C with 2 cooling plates and protection filter)
Ambient Temperature, Storage -40 °C ... +75 °C
Enclosure Protection Rating IP65 (EN 60529)
Physical Dimensions (W x H x D) 36.1 mm x 62.7 mm x 57.7 mm
Housing Material Zinc die-cast (ZNAL4CU1) with acrylic glass (PMMA) optical window
Device Weight Approx. 200 g

Overview

Product Model: DT50-N1124
Product Brand: SICK
Product Series: Dx50

=== General Identification ===
• Part Number: 1047617
• Product Sub-Series / Family: Dx50 DT50 Heated
• Measurement Principle: HDDM™ (High Definition Distance Measurement) Optical Time-of-Flight

=== Technical & Optical Parameters ===
• Measuring / Protective Range: 200 mm … 10,000 mm (90% remission), 200 mm … 6,500 mm (18%), 200 mm … 4,000 mm (6%)
• Light Source: Visible red laser diode (wavelength 658 nm; Class 1 eye-safe per IEC 60825-1:2014; pulse peak 120 mW, pulse duration 2.5 ns)
• Laser Class: Class 1 (IEC 60825-1:2014, EN 60825-1:2014, Eye-safe)
• Response Time: Fast: 20 ms / Slow: 30 ms (Averaging setting)
• Repeatability: ≥ 2.5 mm
• Measurement Accuracy: Typ. ± 10 mm

=== Interface & Electrical Specifications ===
• Output & Communication Interface: Digital Output: 1x NPN (≤ 100 mA); Analog Output: 1x Voltage output (0 V … 10 V, ≥ 5 kΩ, 16-bit); Multifunctional input (MF)
• Supply Voltage: DC 24 V (18 V … 30 V; VS > 15 V required for internal heating element; Reverse-polarity protected)
• Power Consumption: ≤ 28 W (Heater active, without external load)
• Electrical Connection: Male connector M12, 8-pin

=== Mechanical & Environmental Specifications ===
• Ambient Temperature, Operation: -40 °C … +65 °C (Integrated heating; -40 °C … +80 °C with 2 cooling plates; -40 °C … +140 °C with 2 cooling plates and protection filter)
• Ambient Temperature, Storage: -40 °C … +75 °C
• Enclosure Protection Rating: IP65 (EN 60529)
• Physical Dimensions (W x H x D): 36.1 mm x 62.7 mm x 57.7 mm
• Housing Material: Zinc die-cast (ZNAL4CU1) with acrylic glass (PMMA) optical window
• Device Weight: Approx. 200 g

=== Features & Functional Highlights ===
• Direct diffuse distance measurement up to 10 m on natural objects (no reflector required)
• Rugged metal zinc die-cast housing (ZNAL4CU1) engineered for heavy-duty industrial automation
• High-resolution distance measurement with LC display and intuitive menu navigation buttons
• Optical time-of-flight technology (HDDM™) ensuring high repeatability and ambient light stability
• Factory-integrated internal heater for cold-storage and deep-freeze operation down to -40 °C

Common questions

Frequently Asked Questions

What is the part number of this product?

The part number is DT50-N1124, manufactured by SICK. The marking on the unit itself should match this number — confirm the revision code on the nameplate when comparing with your installed hardware.

How do I get a quote for DT50-N1124?

Use the Request a Quote button on this page or send us your model list — pricing, lead time and warranty terms are returned within one business day. A service manual download is available above when applicable.

What are the key specifications of DT50-N1124?

DT50-N1124 is specified as Product Sub-Series / Family: Dx50 DT50 Heated; Measurement Principle: HDDM™ (High Definition Distance Measurement) Optical Time-of-Flight; Measuring / Protective Range: 200 mm ... 10,000 mm (90% remission), 200 mm ... 6,500 mm (18%), 200 mm ... 4,000 mm (6%). The full set of verified technical parameters is listed in the specification table above.

Need this part?

Get pricing, condition and lead time in one business day.