Skip to content

Fast quotes for industrial automation spare parts — send your model list today.

SICK

DL50-P2225 | SICK Rugged metal zinc die-cast housing

High-precision retro-reflective measurement up to 50 m with RS-422 serial interface (accuracy ± 3 mm) Rugged metal zinc die-cast housing (ZNAL4CU1) engineered for heavy-duty industrial automation High-resolution distance measurement with LC display and intuitive menu navigation buttons Optical time-of-flight technology (HDDM™) ensuring high repeatability and ambient light stability Standard operating temperature range -30 °C to +65 °C with official cooling plate expansion capability

Part Number DL50-P2225

  • Inspected and condition-graded before shipping
  • Quote with lead time and warranty in 1 business day
  • Global shipping with protective packaging
Specifications

Technical Details

Part Number 1048418
Product Sub-Series / Family Dx50 DL50 Hi
Measurement Principle HDDM™ (High Definition Distance Measurement) Optical Time-of-Flight
Measuring / Protective Range 200 mm ... 50,000 mm (On Diamond Grade reflective tape)
Light Source Visible red laser diode (wavelength 658 nm; Class 1 eye-safe per IEC 60825-1:2014; pulse peak 120 mW, pulse duration 2.5 ns)
Laser Class Class 1 (IEC 60825-1:2014, EN 60825-1:2014, Eye-safe)
Response Time Fast: 15 ms / Medium: 30 ms / Slow: 80 ms (Averaging setting)
Repeatability ≥ 1 mm
Measurement Accuracy ± 3 mm
Output & Communication Interface Digital Output: 1x PNP (≤ 100 mA); Serial Communication Interface: RS-422; Multifunctional input (MF)
Supply Voltage DC 10 V ... 30 V (Reverse-polarity protected; Limit values; max. 8 A in short-circuit network)
Power Consumption ≤ 2.1 W (Without external load)
Electrical Connection Male connector M12, 5-pin
Ambient Temperature, Operation -30 °C ... +65 °C (Main specification; -30 °C ... +80 °C with 2 cooling plates; -30 °C ... +140 °C with 2 cooling plates and protection filter; Uv ≤ 24 V)
Ambient Temperature, Storage -40 °C ... +75 °C
Enclosure Protection Rating IP65 (EN 60529)
Physical Dimensions (W x H x D) 36.1 mm x 62.7 mm x 57.7 mm
Housing Material Zinc die-cast (ZNAL4CU1) with acrylic glass (PMMA) optical window
Device Weight Approx. 200 g

Overview

Product Model: DL50-P2225
Product Brand: SICK
Product Series: Dx50

=== General Identification ===
• Part Number: 1048418
• Product Sub-Series / Family: Dx50 DL50 Hi
• Measurement Principle: HDDM™ (High Definition Distance Measurement) Optical Time-of-Flight

=== Technical & Optical Parameters ===
• Measuring / Protective Range: 200 mm … 50,000 mm (On Diamond Grade reflective tape)
• Light Source: Visible red laser diode (wavelength 658 nm; Class 1 eye-safe per IEC 60825-1:2014; pulse peak 120 mW, pulse duration 2.5 ns)
• Laser Class: Class 1 (IEC 60825-1:2014, EN 60825-1:2014, Eye-safe)
• Response Time: Fast: 15 ms / Medium: 30 ms / Slow: 80 ms (Averaging setting)
• Repeatability: ≥ 1 mm
• Measurement Accuracy: ± 3 mm

=== Interface & Electrical Specifications ===
• Output & Communication Interface: Digital Output: 1x PNP (≤ 100 mA); Serial Communication Interface: RS-422; Multifunctional input (MF)
• Supply Voltage: DC 10 V … 30 V (Reverse-polarity protected; Limit values; max. 8 A in short-circuit network)
• Power Consumption: ≤ 2.1 W (Without external load)
• Electrical Connection: Male connector M12, 5-pin

=== Mechanical & Environmental Specifications ===
• Ambient Temperature, Operation: -30 °C … +65 °C (Main specification; -30 °C … +80 °C with 2 cooling plates; -30 °C … +140 °C with 2 cooling plates and protection filter; Uv ≤ 24 V)
• Ambient Temperature, Storage: -40 °C … +75 °C
• Enclosure Protection Rating: IP65 (EN 60529)
• Physical Dimensions (W x H x D): 36.1 mm x 62.7 mm x 57.7 mm
• Housing Material: Zinc die-cast (ZNAL4CU1) with acrylic glass (PMMA) optical window
• Device Weight: Approx. 200 g

=== Features & Functional Highlights ===
• High-precision retro-reflective measurement up to 50 m with RS-422 serial interface (accuracy ± 3 mm)
• Rugged metal zinc die-cast housing (ZNAL4CU1) engineered for heavy-duty industrial automation
• High-resolution distance measurement with LC display and intuitive menu navigation buttons
• Optical time-of-flight technology (HDDM™) ensuring high repeatability and ambient light stability
• Standard operating temperature range -30 °C to +65 °C with official cooling plate expansion capability

Common questions

Frequently Asked Questions

What is the part number of this product?

The part number is DL50-P2225, manufactured by SICK. The marking on the unit itself should match this number — confirm the revision code on the nameplate when comparing with your installed hardware.

How do I get a quote for DL50-P2225?

Use the Request a Quote button on this page or send us your model list — pricing, lead time and warranty terms are returned within one business day. A service manual download is available above when applicable.

What are the key specifications of DL50-P2225?

DL50-P2225 is specified as Product Sub-Series / Family: Dx50 DL50 Hi; Measurement Principle: HDDM™ (High Definition Distance Measurement) Optical Time-of-Flight; Measuring / Protective Range: 200 mm ... 50,000 mm (On Diamond Grade reflective tape). The full set of verified technical parameters is listed in the specification table above.

Need this part?

Get pricing, condition and lead time in one business day.