Product Model: DT50-2B215552
Product Brand: SICK
Product Series: Dx50
=== General Identification ===
• Part Number: 1075271
• Product Sub-Series / Family: Dx50-2 Next Generation Distance Sensor
• Measurement Principle: HDDM™ (High Definition Distance Measurement) Optical Time-of-Flight
=== Technical & Optical Parameters ===
• Measuring / Protective Range: 200 mm … 30,000 mm (90% remission), 200 mm … 15,000 mm (18%), 200 mm … 7,000 mm (6%)
• Light Source: Visible red laser diode (wavelength 658 nm; Class 1 eye-safe per IEC 60825-1:2014)
• Laser Class: Class 1 (IEC 60825-1:2014, 658 nm, Eye-safe)
• Response Time: 0.83 ms … 75 ms (Configurable via speed settings)
• Repeatability: ≥ 0.5 mm … 5 mm
• Measurement Accuracy: Typ. ± 7 mm
=== Interface & Electrical Specifications ===
• Output & Communication Interface: Digital Output Q1: 1x Push-Pull (PNP/NPN) / IO-Link V1.1; Analog Output QA: 1x Configurable (4 mA … 20 mA, ≤ 450 Ω / 0 V … 10 V, ≥ 50 kΩ, 16-bit); Multifunctional input (MF)
• Supply Voltage: DC 10 V … 30 V (Reverse-polarity protected; Limit values; max. 8 A)
• Power Consumption: ≤ 2.1 W
• Electrical Connection: Male connector M12, 5-pin
=== Mechanical & Environmental Specifications ===
• Ambient Temperature, Operation: -40 °C … +65 °C
• Ambient Temperature, Storage: -40 °C … +75 °C
• Enclosure Protection Rating: IP65, IP67 (EN 60529)
• Physical Dimensions (W x H x D): 36.2 mm x 67.3 mm x 58 mm
• Housing Material: Zinc die-cast (ZNAL4CU1) with acrylic glass (PMMA) optical window
• Device Weight: Approx. 235 g
=== Features & Functional Highlights ===
• Direct diffuse measurement on natural objects up to 30 m
• Advanced HDDM™ time-of-flight technology offering high measuring rate up to 3 kHz
• Dual interface: Simultaneous digital push-pull switching / IO-Link V1.1 and analog output
• Extended operating temperature range -40 °C to +65 °C without requiring internal heater
• Dual IP65 and IP67 enclosure protection rating for harsh industrial environments