Specifications

Technical Details

Module type Analog input (temperature: thermocouple/RTD/mV/voltage/current)
Channels 4
Signal type Thermocouple (J, K, T, E, N, S, R, B), RTD (PT100, PT1000, NI100, NI1000, CU100), 0-10 Vdc, ±10 Vdc, 0-20 mA, 4-20 mA (software configurable per channel)
Range Per sensor type (e.g., PT100: -200...+850 °C; Type K: -270...+1372 °C)
Resolution 16 bits (15 bits + sign)
Accuracy ±0.2% of full scale at 25 °C (voltage/current/RTD); ±0.4...±0.2% FS for thermocouple depending on type
Isolation 1500 V AC between input and supply; 500 V AC between input and internal logic
Diagnostics Channel status (sensor break, short circuit), module status, bus status
Response time Conversion: 100 ms + 100 ms per channel + 1 controller cycle time (thermocouple); 10 ms per channel sampling
Wiring Removable screw terminal block, 3.81 mm pitch
Supply voltage 24 Vdc (via TM3 bus)
Power consumption Not available
Bus current 45 mA at 5 V DC; 35 mA at 24 V DC
Operating temperature 0...+55 °C

Overview

Modicon TM3 – 4 analog /
temperature inputs (screw) 24Vdc

Main
Range of product Modicon TM3
Product or component type Analog input module
Range compatibility Modicon M221
Modicon M241
Modicon M251
Modicon M262
Analogue input number 4
Analogue input type current 4…20 mA
current 0…20 mA
voltage 0…10 V
voltage – 10…10 V
thermocouple – 200…1000 °C with thermocouple J
thermocouple – 200…1300 °C with thermocouple K
thermocouple 0…1760 °C with thermocouple R
thermocouple 0…1760 °C with thermocouple S
thermocouple 0…1820 °C with thermocouple B
thermocouple – 200…400 °C with thermocouple T
thermocouple – 200…1300 °C with thermocouple N
thermocouple – 200…800 °C with thermocouple E
thermocouple 0…2315 °C with thermocouple C
Ni 100/Ni 1000 temperature probe – 60…180 °C
Pt 100 temperature probe – 200…850 °C
Pt 1000 temperature probe – 200…600 °C
Complementary
Analogue input resolution 16 bits
15 bits + sign
Permissible continuous overload 13 V, analogue input type: voltage
40 mA, analogue input type: current
Input impedance <= 50 Ohm current
>= 1 MOhm voltage
>= 1 MOhm thermocouple
>= 1 MOhm temperature probe
LSB value 2.44 mV 0…10 Vvoltage
4.88 mV – 10…10 Vvoltage
4.88 µA 0…20 mAcurrent
3.91 µA 4…20 mAcurrent
0.1 °Ctemperature probe
0.1 °Cthermocouple
Conversion time 100 ms + 100 ms per channel + 1 controller cycle time for analogue input
thermocouple
100 ms + 100 ms per channel + 1 controller cycle time for analogue input
temperature probe
10 ms + 10 ms per channel + 1 controller cycle time for analogue input voltage/
current
Sampling duration 10 ms, analogue input type: voltage/current
100 ms, analogue input type: voltage/current
100 ms, analogue input type: thermocouple
100 ms, analogue input type: temperature probe

Absolute accuracy error +/- 0.2 % of full scale at 25 °C for analogue input voltage/current
+/- 0.2 % of full scale at 25 °C for Pt 100/Pt 1000, Ni 100/ Ni 1000 temperature probe
+/- 0.2 % of full scale at 25 °C for thermocouple C 0…2315 °C
+/- 6 °C at 25 °C for thermocouple R, S 0…200 °C
+/- 0.2 % of full scale at 25 °C for thermocouple R, S 200…1760 °C
+/- 0.2 % of full scale at 25 °C for thermocouple B 300…1820 °C
+/- 0.4 % of full scale at 25 °C for thermocouple K – 200…0 °C
+/- 0.2 % of full scale at 25 °C for thermocouple K 0…1300 °C
+/- 0.4 % of full scale at 25 °C for thermocouple J – 200…0 °C
+/- 0.2 % of full scale at 25 °C for thermocouple J 0…1000 °C
+/- 0.4 % of full scale at 25 °C for thermocouple E – 200…0 °C
+/- 0.2 % of full scale at 25 °C for thermocouple E 0…800 °C
+/- 0.4 % of full scale at 25 °C for thermocouple T – 200…0 °C
+/- 0.2 % of full scale at 25 °C for thermocouple T 0…400 °C
+/- 0.4 % of full scale at 25 °C for thermocouple N – 200…0 °C
+/- 0.2 % of full scale at 25 °C for thermocouple N 0…1300 °C
Temperature drift +/- 0.01 %FS/°C
Repeat accuracy +/-0.5 %FS
Non-linearity +/- 0.2 %FS
Cross talk <= 1 LSB
[Us] rated supply voltage 24 V DC
Supply voltage limits 20.4…28.8 V
Type of cable Twisted shielded pairs cable <30 m for input circuit
Current consumption 45 mA at 5 V DC via bus connector
50 mA at 5 V DC via bus connector
35 mA at 24 V DC via external supply
40 mA at 24 V DC via external supply
Local signalling 1 LED (green) for PWR
Electrical connection 10 x 1.5 mm² removable screw terminal block with pitch 3.81 mm adjustment for
inputs and supply
10 x 1.5 mm² removable screw terminal block with pitch 3.81 mm adjustment for
inputs
Insulation Between input and supply at 1500 V AC
Between input and internal logic at 500 V AC
Marking CE
Surge withstand 1 kV power supply common mode conforming to IEC 61000-4-5
0.5 kV power supply differential mode conforming to IEC 61000-4-5
1 kV input common mode conforming to IEC 61000-4-5
Mounting support Top hat type TH35-15 rail conforming to IEC 60715
Top hat type TH35-7.5 rail conforming to IEC 60715
plate or panel with fixing kit
Height 90 mm
Depth 70 mm
Width 23.6 mm
Net weight 0.11 kg
Environment
Standards IEC 61131-2
Product certifications CE
UKCA
RCM
EAC
cULus
cULus HazLoc
Resistance to electrostatic
discharge
8 kV in air conforming to IEC 61000-4-2
4 kV on contact conforming to IEC 61000-4-2

Resistance to electromagnetic
fields
10 V/m 80 MHz…1 GHz conforming to IEC 61000-4-3
3 V/m 1.4 GHz…2 GHz conforming to IEC 61000-4-3
1 V/m 2 GHz…3 GHz conforming to IEC 61000-4-3
Resistance to magnetic fields 30 A/m conforming to IEC 61000-4-8
Resistance to fast transients 1 kV (I/O) conforming to IEC 61000-4-4
Resistance to conducted
disturbances
10 V 0.15…80 MHz conforming to IEC 61000-4-6
3 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz) conforming to
Marine specification (LR, ABS, DNV, GL)
Electromagnetic emission Radiated emissions – test level: 40 dBμV/m QP class A ( 10 m) at 30…230 MHz
conforming to IEC 55011
Radiated emissions – test level: 47 dBμV/m QP class A ( 10 m) at 230…1000 MHz
conforming to IEC 55011
Immunity to microbreaks 10 ms
Ambient air temperature for
operation
-10…55 °C horizontal installation
-10…35 °C vertical installation
Ambient air temperature for
storage
-25…70 °C
Relative humidity 10…95 %, without condensation (in operation)
10…95 %, without condensation (in storage)
IP degree of protection IP20
pollution degree 2
Operating altitude 0…2000 m
Storage altitude 0…3000 m
Vibration resistance 3.5 mm at 5…8.4 Hz on DIN rail
3 gn at 8.4…150 Hz on DIN rail
Shock resistance 15 gn for 11 ms
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 7.500 cm
Package 1 Width 10.500 cm
Package 1 Length 12.500 cm
Package 1 Weight 215.000 g

Key specifications

  • Module type: Analog input (temperature: thermocouple/RTD/mV/voltage/current)
  • Channels: 4
  • Signal type: Thermocouple (J, K, T, E, N, S, R, B), RTD (PT100, PT1000, NI100, NI1000, CU100), 0-10 Vdc, ±10 Vdc, 0-20 mA, 4-20 mA (software configurable per channel)
  • Range: Per sensor type (e.g., PT100: -200…+850 °C; Type K: -270…+1372 °C)
  • Resolution: 16 bits (15 bits + sign)
  • Accuracy: ±0.2% of full scale at 25 °C (voltage/current/RTD); ±0.4…±0.2% FS for thermocouple depending on type
  • Isolation: 1500 V AC between input and supply; 500 V AC between input and internal logic
  • Diagnostics: Channel status (sensor break, short circuit), module status, bus status
  • Response time: Conversion: 100 ms + 100 ms per channel + 1 controller cycle time (thermocouple); 10 ms per channel sampling
  • Wiring: Removable screw terminal block, 3.81 mm pitch
  • Supply voltage: 24 Vdc (via TM3 bus)
  • Power consumption: Not available
  • Bus current: 45 mA at 5 V DC; 35 mA at 24 V DC
  • Operating temperature: 0…+55 °C
Common questions

Frequently Asked Questions

What is the part number of this product?

The part number is TM3TI4, manufactured by Schneider Electric. The marking on the unit itself should match this number — confirm the revision code on the nameplate when comparing with your installed hardware.

What condition is this TM3TI4 shipped in?

This unit is offered as refurbished / tested stock: inspected and condition-graded before shipping, packed in protective anti-static material. The current availability and condition grade are confirmed in your quote.

How do I get a quote for TM3TI4?

Use the Request a Quote button on this page or send us your model list — pricing, lead time and warranty terms are returned within one business day. A service manual download is available above when applicable.

What are the key specifications of TM3TI4?

TM3TI4 is specified as Module type: Analog input (temperature: thermocouple/RTD/mV/voltage/current); Channels: 4; Signal type: Thermocouple (J, K, T, E, N, S, R, B), RTD (PT100, PT1000, NI100, NI1000, CU100), 0-10 Vdc, ±10 Vdc, 0-20 mA, 4-20 mA (software configurable per channel). The full set of verified technical parameters is listed in the specification table above.

Need this part?

Get pricing, condition and lead time in one business day.