Manufacturer : Bently Nevada
Product No. :330710-000-050-10-02-00
Product type : 3300 XL 11 mm Proximity Probes
Made in U.S.A
330710 3300 XL 11 mm Probe, M16 x 1.5 thread, with armor
Unthreaded Length Option : 000 = 0 mm
Overall Case Length Option 050 =50mm
Total Length Option : 10 = 1.0 metre (3.3 feet)
Connector and Cable-Type Option : 02 = Miniature coaxial ClickLoc connector, standard cable
Agency Approval Option : 00 = Not required
Probe dc Resistance
Probe
Length (m) 1.0
Resistance from the Center
Conductor to the Outer
Conductor (RPROBE) (ohms)
5.9 ± 0.5
Cross-talk Limitation:
Target Size – Flat Surface
Diameter
Recommended
Minimum 30.5 mm (1.2 in)
Shaft Diameter
Recommended
Minimum 152 mm (6.0 in)
Probe Tip
Material Polyphenylene sulfide (PPS).
Probe Case
Material AISI 304 stainless steel (SST).
Probe Cable
Specification
75 Ω triaxial, fluoroethylene
propylene (FEP) insulated
probe cable in the following
total probe lengths: 1, 5 or 9
meters.
Probe Case Torque
M16x1.5 probe
cases
Maximum
Rated 63.3 N•m (560 in•lb)
Recommended 21.1 N•m (187 in•lb)
Connector-to-connector torque
Recommended
torque Finger tight
Maximum
torque 0.565 N•m (5 in•lb)
Minimum Bend
Radius (with or
without SST
armor)
25.4 mm (1.0 in)
Probe Case Thread M16x1.5
Maximum Length of Thread Engagement 24 mm
Effects of 60 Hz Magnetic Fields Up to 300
Gauss (5 meter system)
Output voltage in mil pp/gauss
Gap 0.5 mm (20mil) Probe 0.001
Gap 2.5 mm (100 mil) Probe 0.009
Gap 4.6 mm (180mil) Probe 0.027
Probe Temperature Range
Operating and
Storage
Temperature
-52°C to +177°C (-62°F to
+351°F)
Exposing the probe to temperatures
below -34°C (30°F) may cause
premature failure of the pressure
seal.
torage
Temperature
-52°C to +105°C (-62°F to
+221°F)
Relative
Humidity
100% condensing, nonsubmersible when
connectors are protected.
Tested to IEC 68-2-3 damp
heat.
Probe
Pressure
3300 XL probes are designed
to seal differential pressure
between the probe tip and
case. The probe sealing
material consists of a Viton
O-ring. Probes are not
pressure tested prior to
shipment. Contact our
custom design department if
you require a test of the
pressure seal for your
application
Temperature Schedule
Temperature Classification
For EPL Ga and Gc
Temperature Classification T1 Ambient Temperature (Probe Only) -55°C to +232°C
Temperature Classification T2 Ambient Temperature (Probe Only) -55°C to +177°C
Temperature Classification T3 Ambient Temperature (Probe Only) -55°C to +120°C
Temperature Classification T4 Ambient Temperature (Probe Only) -55°C to +80°C
Temperature Classification T5 Ambient Temperature (Probe Only) -55°C to +40°C
For EPL Dc
Temperature Classification T280°C @ Ta Ambient Temperature (Probe Only) -55°C to +232°C
Temperature Classification T225°C @ Ta Ambient Temperature (Probe Only) -55°C to +177°C
Temperature Classification T170°C @ Ta Ambient Temperature (Probe Only) -55C to +120°C
Temperature Classification T130°C @ Ta Ambient Temperature (Probe Only) -55°C to +80°C
Temperature Classification T105°C @ Ta Ambient Temperature (Probe Only) -55°C to +100°C
Temperature Classification T90°C @ Ta Ambient Temperature (Probe Only) -55°C to +40°C