Manufacturer : Bently Nevada
Product No. : 330709-000-060-50-11-05
Product type : 3300 XL 11 mm Proximity Probes
Made in U.S.A
330709 =3300 XL 11 mm Probe, M16 x 1.5 thread, without armor
Unthreaded Length Option : 000 = 0 mm
Overall Case Length Option : 060 =60mm
Total Length Option : 50= 5.0 meters (16.4 feet)
Five meter probes are designed for use with the five meter Proximitor Sensor only.
Connector and Cable-Type Option : 11= Miniature coaxial ClickLoc connector with connector
protector, FluidLoc cable
Agency Approval Option : 05= Multiple Approvals
Probe dc Resistance
Probe
Length (m) 5.0
Resistance from the Center
Conductor to the Outer
Conductor (RPROBE) (ohms)
7.2 ± 0.8
Cross-talk Limitation:
Target Size – Flat Surface
Diameter
Recommended
Minimum 30.5 mm (1.2 in)
Shaft Diameter
Recommended
Minimum 152 mm (6.0 in)
Probe Tip
Material Polyphenylene sulfide (PPS).
Probe Case
Material AISI 304 stainless steel (SST).
Probe Cable
Specification
75 Ω triaxial, fluoroethylene
propylene (FEP) insulated
probe cable in the following
total probe lengths: 1, 5 or 9
meters.
Probe Case Torque
M14x1.5 and
M16x1.5 probe
cases
63.3 N•m
(560 in•lb)
21.1 N•m
(187 in•lb)
Connector-to-connector torque
Recommended
torque Finger tight
Maximum
torque 0.565 N•m (5 in•lb)
Minimum Bend
Radius (with or
without SST
armor)
25.4 mm (1.0 in)
Probe Case Thread M16x1.5
Maximum Length of Thread Engagement 24 mm
Probe Temperature Range
Operating and
Storage
Temperature
-52°C to +177°C (-62°F to
+351°F)
Exposing the probe to temperatures
below -34°C (30°F) may cause
premature failure of the pressure
seal.
Probe Case Thread M16x1.5
Maximum Length of Thread
Engagement 24 mm
Probe Case Torque
M14x1.5 and
M16x1.5 probe
cases
Maximum Rated 63.3 N•m (560 in•lb)
Recommended 21.1 N•m (187 in•lb)
Temperature Schedule
(Probe Only)
For EPL Ga and Gc
Temperature Classification T1; Ambient Temperature -55°C to +232°C
Temperature Classification T2 ;Ambient Temperature -55°C to +177°C
Temperature Classification T3; Ambient Temperature -55°C to +120°C
Temperature Classification T4; Ambient Temperature -55°C to +80°C
Temperature Classification T5; Ambient Temperature -55°C to +40°C
For EPL Dc
Temperature Classification T280°C @ Ta ;Ambient Temperature -55°C to +232°C
Temperature Classification T225°C @ Ta ;Ambient Temperature -55°C to +177°C
Temperature Classification T170°C @ Ta; Ambient Temperature -55C to +120°C
Temperature Classification T130°C @ Ta; Ambient Temperature -55°C to +80°C
Temperature Classification T105°C @ Ta; Ambient Temperature -55°C to +100°C
Temperature Classification T90°C @ Ta; Ambient Temperature -55°C to +40°C