The TA2502 is a temperature transmitter from ifm, specified for -50…200 °C.
Measurement is based on 1 x Pt 1000, with a stated range of -50…200 °C.
The output stage provides 1 analogue output and integrates IO-Link communication for parameter setting and diagnostics. Supply voltage is rated 18…32 V DC nominal. The electrical connection is 1 x M12 connector.
The unit operates from -25…80 °C and carries an IP 67 protection rating. Process connection is threaded connection G 1/2 sealing cone.
SpareTechHub supplies the TA2502 as refurbished, tested surplus stock. Request a quote for current pricing, availability and lead time.
Key specifications
| Measuring range | -50…200 °C (factory setting: 0…200 °C) |
|---|---|
| Process connection | threaded connection G 1/2 sealing cone |
| Housing material | stainless steel (1.4404 / 316L); PEI; FKM |
| Electrical connection | 1 x M12 connector, coding A |
| Supply voltage | 18…32 V DC nominal (“supply class 2” per cULus) |
| Outputs | 1 analogue output; output signal: analogue signal + IO-Link (configurable) |
| Protocols | IO-Link; transmission COM2 (38.4 kBaud); IO-Link revision 1.1 |
| Protection rating | IP 67; IP 68; IP 69K |
| Operating temperature | -25…80 °C (medium temperature < 160 °C); -25…60 °C (medium temperature < 200 °C) |
| Wetted materials | stainless steel (1.4404 / 316L), electropolished |
| Dimensions (H×W×D) | 180.5 g device, Ø 18.7 mm housing diameter (official publishes housing diameter and probe length; no rectangular H×W×D table) |
| Weight | 180.5 g |