When a communication adapter fails on a running Modicon Momentum system, unplanned downtime compounds hour by hour. Sourcing a tested 170INT11003 fast matters. This Schneider Electric communication adapter connects devices over Interbus Generation SUPI III, and SpareTechHub supplies inspected, condition-graded units ready for dispatch.
What Is this unit Communication Adapter?
this unit belongs to Schneider Electric’s Modicon Momentum series. It handles data exchange between devices using a master/slave access method and a continuous shift register. The adapter supports 0 to 254 devices per segment, so one unit can serve a populated network segment. A ring network topology keeps the data path predictable, while CRC-16 control parameters verify transmission integrity. Two 9-pin D-Sub Interbus connectors provide the electrical interface, and twisted-pair cable is the specified transmission medium. The module carries an IP20 protection class, so it suits cabinet-mounted installations rather than exposed plant-floor locations.

Technical Specs That Matter on the Floor
Three values shape how this adapter fits an existing Interbus segment. First, the transmission rate is 500 kilobits per second, which sets the pace of data handling across the ring. Second, the maximum cable distance between devices exceeds 3,280 feet (1,000 meters), and between two modules it is 1,312.14 feet (400 meters) — useful when adapter and controlled devices sit far apart. Third, power dissipation is 0.8 Watt without a fiber-optic adapter, so the unit adds little heat inside an enclosure. Ambient operating temperature is 0 to 60°C in a non-condensing environment, and operating altitude is less than 16,404 feet (5,000 meters). Storage temperature spans -40 to 85°C, also non-condensing.

Why a Tested Spare Beats Waiting on Factory Lead Times
For legacy Modicon Momentum installations, factory lead times can stretch while a line sits idle. SpareTechHub buys, repairs, tests and resells automation spare parts, so this this unit is inspected and functionally checked before dispatch. Each unit is condition clearly graded, and you know what you are installing before it arrives. That approach gives maintenance teams faster availability than factory lead times and a practical alternative when a like-for-like replacement is needed. Because the adapter uses standard 9-pin D-Sub Interbus connectors and twisted-pair cabling, swap-out follows the existing wiring plan. Send the exact part number to SpareTechHub for a tested-unit quote within one business day.