The Allen-Bradley 1756-CNB/E is a ControlNet Bridge Module for industrial control and automation applications.
The Allen-Bradley 1756-CNB/E is a ControlNet bridge module for the ControlLogix platform, discontinued on 2024-12-31 with the 1756-CN2 listed as replacement. Maintenance teams still running ControlNet need a tested spare for this exact Series E module rather than a factory lead-time wait.
Product Overview and Cost Implications
This bridge connects ControlLogix controllers to a ControlNet network at 5 Mbps and supports up to 99 nodes. The dual-port RG-6 coax design allows redundant cabling, so a single cable fault does not stop scheduled messaging. For a running line, that redundancy protects throughput and avoids unplanned downtime cost. The module draws 750 mA at 5 V and 10 mA at 24 V from the chassis backplane, and 30 V isolation separates network and chassis circuits. It mounts in any 1756 chassis slot, so no rewiring of the rack is needed when swapping a failed unit. Because this module is discontinued, sourcing a tested unit is often faster than waiting on factory allocation, and it keeps existing ControlNet segments running without a forced migration.

Tested-Parts Advantage
Every this module we supply is inspected and functionally checked before dispatch, with condition clearly graded. That matters for a discontinued bridge: a failed module can halt scheduled ControlNet traffic and stall the controller’s view of remote I/O. A tested spare shortens the repair window and avoids the cost of expediting a replacement platform. We verify markings and part-number cross-reference against the OEM datasheet, so you receive the Series E configuration you ordered. Units are graded honestly, and our team works with these systems daily, so quoting is responsive. Availability is typically faster than factory lead times on discontinued items, and worldwide shipping is arranged from our stock.

Sourcing Guide and Replacement Path
Confirm the exact part number, including the /E suffix, before ordering, because the base catalog 1756-CNB has multiple series revisions. Note that Rockwell lists the 1756-CN2 as the replacement, so plan whether you are maintaining an existing ControlNet segment or migrating. If maintaining, verify chassis slot availability and backplane power budget against the 750 mA at 5 V and 10 mA at 24 V draw. Also confirm the condition grade you need and whether the dual-port coax cabling is already in place. Send the exact part number to SpareTechHub for a tested-unit quote within one business day.