Manufacturer : Bently Nevada
Product No. : 330702-00-30-50-02-00
Product type : 3300 XL 11 mm Proximity Probes
Made in U.S.A
330702 = 3300 XL 11 mm Probe, 1/2-20 UNF
thread, with armor
Unthreaded Length Option : 00= 0.0 in
Overall Case Length Option :30 =3.0 in
Total Length Option : 50 = 5.0 meters (16.4 feet)
Five meter probes are designed for use with the five meter Proximitor Sensor only
Connector and Cable-Type Option : 02 = Miniature coaxial ClickLoc
connector, standard cable
Agency Approval Option : 00 = Not required
Probe Tip Material: Polyphenylene sulfide (PPS).
Probe Case Material: AISI 304 stainless steel (SST).
Probe Cable Specifications: 75 Ω triaxial, fluoroethylene propylene (FEP) insulated probe cable in the following total probe lengths: 1, 5 or 9 metres.
Operating and Storage Temperature: -51°C to +177°C (-60°F to +351°F)
Probe Pressure: 3300 XL probes are designed to seal differential pressure between the probe tip and case. The probe sealing material consists of a Viton* O-ring. Probes are not pressure tested prior to shipment. Contact our custom design department if you require a test of the pressure seal for your application
Shipping weight : 0.17 Kg
Probe dc Resistance
Probe
Length (m) 5.0
Resistance from the Center
Conductor to the Outer
Conductor (RPROBE) (ohms)
7.2 ± 0.8
Probe Case Thread 1/2-20
Maximum Length of Thread Engagement 0.750 in
Probe Case Torque
1/2-20 and 5/8-18 probe cases
Maximum Rated 45.2 N•m (400 in•lb)
Recommended 15.2 N•m (133 in•lb)
Probe Tip
Material Polyphenylene sulfide (PPS).
Probe Case
Material AISI 304 stainless steel (SST).
Probe Cable
Specification
75 Ω triaxial, fluoroethylene
propylene (FEP) insulated
probe cable in the following
total probe lengths: 1, 5 or 9
meters.
Connector-to-connector torque
Recommended
torque Finger tight
Maximum torque 0.565 N•m (5 in•lb)
Minimum Bend Radius (with or without SST armor) 25.4 mm (1.0 in)
Probe Case Thread M16x1.5
Maximum Length of Thread Engagement 24 mm
Probe Temperature Range
Operating and
Storage
Temperature
-52°C to +177°C (-62°F to
+351°F)
Exposing the probe to temperatures
below -34°C (30°F) may cause
premature failure of the pressure
seal.
Effects of 60 Hz Magnetic Fields Up to 300 Gauss (5 meter system)
Output voltage in mil pp/gauss
Gap 0.5 mm (20 mil)
Proximitor Sensor 0.006
Probe 0.001
Ext. Cable 0.001
Gap 2.5 mm (100mil)
Proximitor Sensor 0.033
Probe 0.009
Ext. Cable 0.005
Gap 4.6 mm (180 mil))
Proximitor Sensor 0.033
Probe 0.027
Ext. Cable 0.007
Probe Case Thread 1/2-20
Maximum Length of Thread Engagement 0.750 in
Gold-plated brass
Probe case torque: ½-20 and 5⁄8 -18 probe cases
Maximum Rated: 45.2 N•m (400 in•lb)
Recommended: 15.0 N•m (133 in•lb)
Temperature Schedule
(Probe Only)
For EPL Ga and Gc
Temperature Classification T1 Ambient Temperature -55°C to +232°C
Temperature Classification T2 Ambient Temperature -55°C to +177°C
Temperature Classification T3 Ambient Temperature -55°C to +120°C
Temperature Classification T4 Ambient Temperature -55°C to +80°C
Temperature Classification T5 Ambient Temperature -55°C to +40°C
For EPL Dc
Temperature Classification T280°C @ Ta Ambient Temperature -55°C to +232°C
Temperature Classification T225°C @ Ta Ambient Temperature -55°C to +177°C
Temperature Classification T170°C @ Ta Ambient Temperature -55C to +120°C
Temperature Classification T130°C @ Ta Ambient Temperature -55°C to +80°C
Temperature Classification T105°C @ Ta Ambient Temperature -55°C to +100°C
Temperature Classification T90°C @ Ta Ambient Temperature -55°C to +40°C