Product Model: DT50-N1113
Product Brand: SICK
Product Series: Dx50
=== General Identification ===
• Part Number: 1047396
• Product Sub-Series / Family: Dx50 DT50 Standard
• Measurement Principle: HDDM™ (High Definition Distance Measurement) Optical Time-of-Flight
=== Technical & Optical Parameters ===
• Measuring / Protective Range: 200 mm … 10,000 mm (90% remission), 200 mm … 6,500 mm (18%), 200 mm … 4,000 mm (6%)
• Light Source: Visible red laser diode (wavelength 658 nm; Class 2 per IEC 60825-1:2014; average optical power < 1 mW, pulse peak 180 mW, pulse duration 5 ns)
• Laser Class: Class 2 (IEC 60825-1:2014, EN 60825-1:2014)
• Response Time: Fast: 20 ms / Slow: 30 ms (Averaging setting)
• Repeatability: ≥ 2.5 mm
• Measurement Accuracy: Typ. ± 10 mm
=== Interface & Electrical Specifications ===
• Output & Communication Interface: Digital Output: 1x NPN (≤ 100 mA); Analog Output: 1x Current output (4 mA … 20 mA, ≤ 300 Ω, 16-bit); Multifunctional input (MF)
• Supply Voltage: DC 10 V … 30 V (Reverse-polarity protected; Limit values; max. 8 A in short-circuit network)
• Power Consumption: ≤ 2.1 W (Without external load)
• Electrical Connection: Male connector M12, 5-pin
=== Mechanical & Environmental Specifications ===
• Ambient Temperature, Operation: -30 °C … +65 °C (Main specification; -30 °C … +80 °C with 2 cooling plates; -30 °C … +140 °C with 2 cooling plates and protection filter; Uv ≤ 24 V)
• Ambient Temperature, Storage: -40 °C … +75 °C
• Enclosure Protection Rating: IP65 (EN 60529)
• Physical Dimensions (W x H x D): 36.1 mm x 62.7 mm x 57.7 mm
• Housing Material: Zinc die-cast (ZNAL4CU1) with acrylic glass (PMMA) optical window
• Device Weight: Approx. 200 g
=== Features & Functional Highlights ===
• Direct diffuse distance measurement up to 10 m on natural objects (no reflector required)
• Rugged metal zinc die-cast housing (ZNAL4CU1) engineered for heavy-duty industrial automation
• High-resolution distance measurement with LC display and intuitive menu navigation buttons
• Optical time-of-flight technology (HDDM™) ensuring high repeatability and ambient light stability
• Standard operating temperature range -30 °C to +65 °C with official cooling plate expansion capability