Model: NU-EN8N
Brand: Keyence
Series: NU
e-CON input unit for NU series network communication units.
Hardware
I/O: 8 inputs via e-CON 4-pin connector; NPN open-collector or contact; response 20 us or less; input resistance 2.4 kOhm; min ON 6 V; max OFF current 0.9 mA; supply current 520 mA or less (8 ports)
Sensor connection: N-bus compatible amplifiers, max. 16 units; passing current 1,200 mA or less total
I/O Specifications
N-bus sensor amplifier connection via wiring-saving connector
Communication
Built-in ports: e-CON 4-pin x8
Protocols: N-bus (via connected NU communication unit)
Communication expansion: None
Electrical
Supply voltage: 12 to 24 VDC +/-10% (from connected communication unit)
Power consumption: Not available
Environmental
Operating temperature: -20 to +55 °C (no freezing)
Storage temperature: Not available
Relative humidity: 35 to 85% RH (no condensation)
Protection rating: Not available
Physical
Dimensions (H×W×D): Not available
Weight: Approx. 0.055 kg (incl. tag)
Lifecycle
Active; official Keyence production status confirmed via product/spec page (Last verified: 2026-09)