Product Model: S30A-6011DB
Product Brand: SICK
Product Series: S3000
=== General Identification ===
• Part Number: 1026401
• Product Sub-Series / Family: S3000 Professional CMS
• Measurement Principle: 2D LiDAR Optoelectronic Pulsed Laser Safety Scanning (Time-of-Flight)
=== Technical & Optical Parameters ===
• Measuring / Protective Range: Protective field range: 5.5 m; Warning field range: 49 m radial warning field
• Light Source: Pulsed laser diode (wavelength 905 nm; Class 1 eye-safe per IEC 60825-1:2014; average optical power < 1 mW)
• Laser Class: Class 1 (IEC 60825-1:2014, EN 60825-1:2014, Eye-safe)
• Response Time: ≤ 60 ms (Configurable via multiple sampling rate: 60 ms … 120 ms)
• Scanning Angle: 190° scanning angle (0.25° or 0.5° angular resolution)
• Object Resolution: 30 mm / 40 mm / 50 mm / 70 mm / 150 mm (Configurable depending on resolution setup)
• Safety Integrity Level: Type 3 (IEC 61496-1, -3), SIL 2 (IEC 61508), SILCL 2 (EN 62061), PL d / Category 3 (EN ISO 13849-1)
• Measurement Accuracy: Systematic measurement error: Typ. ± 35 mm
=== Interface & Electrical Specifications ===
• Output & Communication Interface: Safety Outputs: 1x OSSD pair (PNP, 250 mA); Raw measurement data output (RS-422 CMS protocol); Safe EFI bus
• Supply Voltage: DC 24 V (16.8 V … 28.8 V; SELV/PELV safety extra-low voltage)
• Power Consumption: Typ. 19 W (Without external output loads)
• Electrical Connection: System plug with RS-422 data cable gland
=== Mechanical & Environmental Specifications ===
• Ambient Temperature, Operation: -10 °C … +50 °C
• Ambient Temperature, Storage: -20 °C … +70 °C
• Enclosure Protection Rating: IP65 (EN 60529)
• Physical Dimensions (W x H x D): 155 mm x 185 mm x 160 mm
• Housing Material: Aluminum die-cast with polycarbonate (PC) optical hood
• Device Weight: Approx. 3.3 kg
=== Features & Functional Highlights ===
• Simultaneous safety protection (5.5 m protective field) and AGV navigation via CMS contour data
• Contour Measurement System (CMS) outputs real-time distance and angle raw measurement data over RS-422
• 8 field sets, 16 monitoring cases, and encoder speed monitoring