Skip to content

Fast quotes for industrial automation spare parts — send your model list today.

SICK

SICK LMS111-10100 2D Laser Scanner 18 m Range IP67

SICK LMS111-10100 2D laser scanner with 18 m range at 10% remission, IP67 housing, and TCP/IP plus RS-232 interfaces — tested and graded before dispatch.

Part Number LMS111-10100

Refurbished / Tested

  • Inspected and condition-graded before shipping
  • Quote with lead time and warranty in 1 business day
  • Global shipping with protective packaging
Specifications

Technical Details

Working range 0.5 m ... 20 m
Scanning range at 10% remission 18 m
Scanning frequency 25 Hz / 50 Hz
Aperture angle (horizontal) 270°
Supply voltage 10.8 V DC ... 30 V DC
Enclosure rating IP67 (EN 60529, Section 14.2.7)
Operating temperature –30 °C ... +50 °C
Weight 1.1 kg

Overview

The SICK LMS111-10100 is a Connection type 1 x M12 round connector for industrial control and automation applications.

The SICK LMS111-10100 is a 2D laser scanner for indoor and outdoor use, rated for an 18 m scanning range at 10% remission and housed to IP67. Maintenance teams choose a tested spare for this exact model because a verified unit shortens the gap between a scanner fault and a running line.

Why this unit Fits Demanding Scan Positions

This scanner pairs a 270° horizontal aperture angle with 25 Hz and 50 Hz scanning frequency options, so engineers can match update rate to the process rather than the other way round. The infrared 905 nm light source sits in laser class 1 (IEC 60825-1:2014, EN 60825-1:2014+A11:2021), which keeps the optical path simple to specify. A working range of 0.5 m to 20 m and 20 m scanning range at 90% remission cover long approach zones, while 18 m at 10% remission suits darker targets. Ten field sets with ten simultaneous evaluation cases let one unit handle several detection zones without extra hardware. Integrated heating extends use into cold areas, and the 1.1 kg housing measures 105 mm x 102 mm x 162 mm.

Figure 1: Front view of the SICK LMS111-10100 Connection type 1 x M12 round connector showing its physical design and enclosure.

Tested-Parts Advantage for This Scanner

Factory lead times rarely match a stopped line, so SpareTechHub keeps tested units moving instead. Each this unit is inspected and functionally checked before dispatch, and its condition is clearly graded so buyers know what arrives. The 1 x M12 round connector, 10.8 V DC to 30 V DC supply range, and TCP/IP plus RS-232 data interfaces are verified against the unit markings. Because the scanner does not constitute a safety component under machine safety legislation, it belongs in standard automation roles. A verified spare also removes the wait that comes with ordering new OEM stock.

Figure 2: Technical layout and connection details for the SICK LMS111-10100 Connection type 1 x M12 round connector.

Integration and Sourcing Checks Before You Order

Confirm the exact model and revision, then check that the 10/100 MBit/s Ethernet and 9.6 kBaud to 115.2 kBaud serial links match your controller plan. Review the 2 digital and 2 encoder inputs plus 3 outputs against your I/O budget, and note the 7-segment display with 5 status LEDs for setup feedback. The IP67 rating and -30 °C to +50 °C operating temperature set the enclosure and ambient expectations. Send the exact part number to SpareTechHub for a tested-unit quote within one business day.

Common questions

Frequently Asked Questions

What is the part number of this product?

The part number is LMS111-10100, manufactured by SICK. The marking on the unit itself should match this number — confirm the revision code on the nameplate when comparing with your installed hardware.

What condition is this LMS111-10100 shipped in?

This unit is offered as refurbished / tested stock: inspected and condition-graded before shipping, packed in protective anti-static material. The current availability and condition grade are confirmed in your quote.

How do I get a quote for LMS111-10100?

Use the Request a Quote button on this page or send us your model list — pricing, lead time and warranty terms are returned within one business day. A service manual download is available above when applicable.

What are the key specifications of LMS111-10100?

LMS111-10100 is specified as Working range: 0.5 m ... 20 m; Scanning range at 10% remission: 18 m; Scanning frequency: 25 Hz / 50 Hz. The full set of verified technical parameters is listed in the specification table above.

Need this part?