Siemens SIRIUS 3RW Soft Starters Guide

SIRIUS 3RW is Siemens’ thyristor soft-starter family for motor control. It limits inrush current with a ramp and reduces mechanical and electrical stress on start. The most common field mistake is not a wrong brand but a one-character suffix error: 3RW44 and 3RW40 are different generations and current classes, and within a platform 3RW44xx-6BC44 and -1BC44 differ in voltage and control wiring. Below is a cross-reference of the 20 models we cover, built from the nameplate data in each source page, plus how to read the ordering code and avoid returns.

What the 3RW models are

The 3RW44 platform is the higher-current SIRIUS soft starter; 3RW40 is the earlier, lower-power
generation. Both are IP00 open-frame units intended for enclosure mounting. Current and power
ratings below are the nameplate values published for each model.

Model cross-reference (20 models)

Model Current (rated) Power @400 V Notes
3RW4455-6BC44 693 A 400 kW Delta-in 1200 A / 710 kW
3RW4454-6BC44 615 A 355 kW —
3RW4453-6BC44 551 A 315 kW 67 kg
3RW4447-6BC44 — — see nameplate
3RW4446-6BC44 617 A — control 230 V AC
3RW4445-6BC44 313 A 160 kW busbar connection
3RW4444-6BC44 250 A 132 kW busbar connection
3RW4443-6BC44 — — see nameplate
3RW4436-6BC44 162 A 90 kW —
3RW4435-6BC44 134 A 75 kW busbar connection
3RW4434-6BC44 113 A 55 kW busbar connection
3RW4427-1BC44 — — see nameplate
3RW4426-1BC44 77 A 37 kW box-terminal
3RW4425-1BC44 57 A 30 kW —
3RW4424-1BC44 47 A 22 kW —
3RW4423-1BC44 36 A 18.5 kW box-terminal
3RW4422-1BC44 — — see nameplate
3RW4076-6BB44 — — 3RW40 gen., see nameplate
3RW4075-6BB44 — — 3RW40 gen., see nameplate
3RW4074-6BB44 57 A 30 kW 3RW40 gen.

Current and power are the nameplate values we published per model. The -6BC44 vs
-1BC44 suffix difference denotes a different voltage / control-supply / option coding.
Confirm the full suffix against the nameplate of the unit being replaced.

Reading the 3RW ordering code

Using 3RW44 55 -6BC44 as the example: 3RW = family; 44 = current
platform grade; 55 = the specific current step within that platform; -6BC44 =
voltage / control-supply / option code. Within a platform a one-character suffix difference is a
different orderable item — the most frequent cause of returns.

Common sourcing mistakes

  • Checking only the front segment. 3RW4445 matches but -6BC44
    vs -1BC44 have different control wiring — arrives and will not fit.
  • Substituting a close relative. Same platform, similar look, different current/voltage step;
    overspec or underspec both cause problems.
  • Ignoring condition. Thyristors age; a surplus/refurbished unit needs a test report, not just a photo.

Condition reality: new, surplus, and refurbished

Industrial spares circulate in three conditions, and the label changes the risk profile:

  • New / factory-sealed — lowest risk, highest price; verify the seal and date code.
  • Surplus (new-unused, pulled from decommissioned lines) — often the best value; confirm it was stored dry and static-safe.
  • Refurbished / tested — acceptable only with a functional test report; ask what was tested and to what standard.

For any electronic or power module, insist on a test report before payment. Appearance alone does not prove function, and a failed module on a live line costs far more than the saving.

Frequently asked questions

Can a 3RW44 directly replace a 3RW40?

No — different platform and current class. Re-select against the nameplate.

Does a one-character suffix difference matter?

Yes — it can be a different orderable item with different voltage or control wiring.

How do I confirm condition?

Request a functional test report; refurbished units should include test records.

This guide merges the individual model pages we previously published into one reference. The old per-model pages now redirect here. If you arrived from a specific model link, use the model list and ordering-code section below to land on the right part.