Keyence GL-R, GL-V and GL-S Safety Light Curtains: Selection Guide

Yellow articulated robots working inside fenced safety cells on a production line, with red stack lights at each cell

The Keyence GL family is the safety light curtain range we stock most widely: 191 published listings across GL-R, GL-V and GL-S in the SpareTechHub catalogue, split into finger, hand and body protection classes. This guide compares the three series on the specifications printed in each product record — detection capability, beam count, guarded height, operating distance and OSSD response time — so a maintenance or controls engineer can shortlist the right set before ordering an emitter and receiver pair.

For the other Keyence families covered in this catalogue, start from the Keyence sensors, vision systems and PLCs buying guide, which links every series guide together.

How do the GL-R, GL-V and GL-S safety light curtains differ?

The GL-R is the general-purpose Type 4 curtain with finger, hand and body variants, the GL-V moves those three classes into a small metal housing for harsh cells, and the GL-S is a compact flat or slim curtain limited to 2 m. All three use 24 VDC OSSD outputs.

  • GL-R: 53 catalogue listings — 19 finger (ø14 mm), 19 hand (ø25 mm) and 15 body (ø45 mm) models.
  • GL-V: 120 listings — 40 finger, 40 hand and 40 body models, each offered in NPN and PNP output versions.
  • GL-S: 18 listings, all hand protection at ø25 mm, in flat (FH) and slim (SH) housings.

Which GL-R model covers finger, hand and body protection?

Detection capability decides the GL-R suffix: F models detect a ø14 mm finger, H models a ø25 mm hand and L models a ø45 mm body. Longer guarded heights add beam axes but never change that threshold, so the suffix should follow the access width and required safety distance.

Model Protection type Detection capability Beam axes / spacing Detection height Total length Detecting distance OSSD response
GL-R31F Finger ø14 mm 31 / 10 mm 300 mm 320 mm 0.2 to 10 m max. 7.8 ms
GL-R08H Hand ø25 mm 8 / 20 mm 140 mm 160 mm 0.2 to 15 m max. 6.6 ms
GL-R10L Body ø45 mm 10 / 40 mm 360 mm 400 mm 0.2 to 15 m max. 6.6 ms
  • GL-R finger models reach 0.2 to 10 m with a maximum OSSD response of 7.8 ms; hand and body models reach 0.2 to 15 m at 6.6 ms, according to the GL-R31F, GL-R08H and GL-R10L records.
  • Beam spacing follows the class: 10 mm on finger models, 20 mm on hand models and 40 mm on body models, which is why a 10-axis body curtain guards 360 mm while an 8-axis hand curtain guards 140 mm.
  • Every GL-R set is supplied as transmitter plus receiver. Optical or wire synchronization is selected by wiring, and up to two GL-R systems can be mounted together with the channel A/B switch.

What does the GL-V metal-housing range change for harsh cells?

GL-V models use an aluminium alloy body and a wider operating window rather than a different safety principle: the series stays Type 4, SIL 3 and Category 4 PL e, but runs from -30 to +55 °C, detects at 0.3 to 12 m and responds in 5.1 ms or less, which suits welding and machining cells.

  • GL-VM31FP: finger protection at ø14 mm with 31 beam axes on 10 mm spacing, 300 mm detection height, 320 mm total length, 0.3 to 12 m, max. 5.1 ms, PNP OSSD rated 150 mA, 24 VDC -20/+25%, 850 nm infrared LED, IP65/IP67.
  • The GL-V range is split evenly: 40 finger, 40 hand and 40 body listings, and every model exists in both NPN and PNP output versions, so the output type is a catalogue choice rather than a custom order.
  • GL-V synchronization is optical only and interference is handled by series connection plus switch setting for up to two units, which is a different wiring approach from the GL-R dual synchronization modes.

When is the compact GL-S series the right choice?

Pick the GL-S when the guarded opening is small and the curtain must fit inside a machine frame: all 18 listings are ø25 mm hand-protection sets with a 0.1 to 2 m operating distance, and the flat FH housing is 179.5 mm long at 8 beams.

  • GL-S08FH: flat type, 8 beams on 20 mm spacing, 140 mm detection height, 179.5 mm total length, 0.1 to 2 m, max. 6.6 ms, 2 OSSD outputs rated 300 mA, -10 to +50 °C, IP65/IP67.
  • The effective aperture angle is max. ±3.75° at 2 m on this model, compared with ±2.5° at 3 m or more on the GL-R, so reflective surfaces near the optical path need more attention at the shorter range.
  • GL-S models are offered as flat (FH) and slim (SH) versions with the same 8-beam, 20 mm-spacing geometry, so the choice is about mounting space rather than detection performance.

What do the three GL families have in common?

All three families are Type 4 ESPE/AOPD sets with two transistor OSSD outputs, 24 VDC supply and IP65/IP67 protection, and all are listed to IEC 61496-1/-2, IEC 61508 SIL 3, IEC 62061 SIL CL3, EN ISO 13849-1 Category 4 PL e and UL 508/UL 1998, so replacement screening can focus on class, range and housing.

  • GL-R and GL-R hand/body models accept 24 VDC ±20%; GL-V accepts 24 VDC -20/+25%; both tolerate 10% ripple or less and are Class 2 supplied.
  • OSSD load ratings differ by family: 500 mA on GL-R, 150 mA on the GL-VM31FP record and 300 mA on GL-S08FH, so the downstream safety relay input rating has to be checked against the chosen family.
  • Ambient light immunity is quoted the same way across the records: incandescent lamp 3,000 lux or less and sunlight 20,000 lux or less.

How do you build a complete order from the catalogue?

Start from the protection class, then confirm guarded height, operating distance and output type, and order the transmitter and receiver as the set the model number describes. The category pages list every model with its beam count and total length, while each product record carries the full electrical and standards table.

  • Browse GL-R series listings (53 models), GL-V series listings (120 models) and GL-S series listings (18 models) to compare beam counts side by side.
  • Check the connection hardware before ordering: GL-R and GL-S sets use transmitter/receiver cables with PNP or NPN OSSD determined by cable type, so the cable variant is part of the model number.
  • If a guard needs more than one curtain, check the interference limit before ordering: the GL-R record allows up to two systems with the channel A/B switch, the GL-V record allows up to two units by series connection and switch setting, and the GL-S08FH record states no interference limit.

Frequently asked questions

What does Type 4 mean on a Keyence GL light curtain?

Type 4 is the highest ESPE classification in IEC 61496-1/-2 and appears in the specification table of every GL-R, GL-V and GL-S record we list, together with IEC 61508 SIL 3, IEC 62061 SIL CL3 and EN ISO 13849-1 Category 4 PL e. In practice it means the curtain is built for presence-sensing safeguarding where a single fault must not lose the safety function, and the machine builder still has to calculate the safety distance and validate the whole loop, including the relay or safety controller that reads the two OSSD outputs.

Can a GL-R finger curtain replace a GL-R hand curtain on the same machine?

Only after the safety distance is recalculated. The GL-R31F detects ø14 mm on 10 mm beam spacing, while the GL-R08H detects ø25 mm on 20 mm spacing, and the finer capability requires a longer minimum distance from the hazard under ISO 13855. The mechanical length also changes: 320 mm total on the 31-axis finger model against 160 mm on the 8-axis hand model, so brackets and guarded openings usually need review as well.

Is the GL-V a direct replacement for a GL-R set?

They share the same Type 4 safety ratings but not the same electrical envelope. The GL-VM31FP runs 0.3 to 12 m with a 5.1 ms response, 150 mA OSSD load and PNP output, whereas a GL-R31F runs 0.2 to 10 m at 7.8 ms with a 500 mA load and an output type set by cable. Mounting, synchronization and relay compatibility have to be checked per model rather than assumed from the shared family name.

Why is the GL-S limited to 2 m?

The GL-S is a compact flat or slim curtain intended to sit inside machine frames, and its record quotes 0.1 to 2 m with a ±3.75° effective aperture angle at 2 m. The lower range keeps the housing small and the unit weight at about 95 g, which suits short openings and close mounting; long conveying lines and wide perimeter guards are better served by a GL-R or GL-V set with its 10 to 15 m range.

How many beams do I need for a given opening height?

Work from detection height rather than beam count. The records show that beam count multiplied by beam spacing plus one spacing gives the guarded height: 31 beams at 10 mm give 300 mm on the GL-R31F, 10 beams at 40 mm give 360 mm on the GL-R10L and 8 beams at 20 mm give 140 mm on the GL-R08H. Select the height that covers the whole access opening, then check that the resulting total length fits the frame.

Are NPN and PNP versions both available across the GL range?

GL-V is the family where this is explicit: all 120 listings divide evenly into NPN and PNP variants across finger, hand and body classes. GL-R and GL-S records state that the OSSD output is PNP or NPN depending on the cable type, so on those families the output is fixed by the cable variant you order and cannot be switched afterwards.

What ambient conditions do the GL curtains tolerate?

The GL-R and GL-S records quote -10 to +55 °C and -10 to +50 °C respectively, both with 15 to 85% RH non-condensing and IP65/IP67 protection. The GL-V extends the range to -30 to +55 °C with up to 95% RH, and adds declared vibration and shock figures, which is the reason it is the usual choice for foundry, welding and heavy machining areas.

Do I need a separate safety relay with a GL curtain?

The curtain provides two transistor OSSD outputs but no internal safety-rated relay contacts, so the machine circuit still needs a safety relay or safety controller that monitors both channels. Match its input rating to the OSSD load of the chosen model — 500 mA on GL-R, 300 mA on GL-S08FH and 150 mA on GL-VM31FP — and keep the response time of the relay in the overall stopping-time calculation.