Skip to content

Fast quotes for industrial automation spare parts — send your model list today.

Keyence GT2, GT and IL Measurement Sensors: Selection Guide

Robotic arm loading a machined part into a CNC machining centre, with finished metal parts on a fixture in the foreground

Keyence measurement sensors split into two physical approaches: a contact spindle that touches the part, and a laser that measures it from a distance. The SpareTechHub catalogue holds 73 Keyence listings in this group — 47 GT2 items, 14 GT items, 11 IL items and 1 LK-G item — covering contact heads, contact amplifiers, laser displacement heads and laser amplifiers. This guide compares them on measuring range, resolution, accuracy, measuring force and sampling speed, using the numbers recorded on each product page.

Measurement is one of four series guides here; the Keyence buying guide covers the safety, sensing, vision and controller groups as well.

Should I measure with a contact head or a laser?

A contact head is the choice when the surface is stable, the feature is hard to reach optically or the measurement must not depend on colour and reflectivity, while a laser head suits soft, moving or hot parts and thin features that a spindle would deflect. Contact heads also quote a measuring force, which a laser does not.

  • GT2-H12 is a box-type contact head with a 12 mm measuring range and 1.0 N measuring force downward, 0.9 N side-mounted and 0.8 N upward.
  • IL-030 is a reflective CMOS laser head with a 20 to 45 mm measurement range around a 30 mm reference distance, so it never touches the target.
  • The trade-off is resolution against application fit: the contact GT2-S5 reaches 0.1 µm resolution, while the IL-030 quotes 1 µm repeatability at 1 ms sampling.

What do the GT2 head prefixes mean?

GT2 head part numbers encode the mounting style, not the accuracy: H is the box type, PA and S are pencil types, A is air push and P is the stylus high-precision type, with K marking high-precision and L marking low-stress. The number after the prefix is the stroke in millimetres.

  • Box heads: GT2-H12, GT2-H12K, GT2-H12L and GT2-H12KL share the 12 mm stroke, then GT2-H32 and GT2-H50 extend the stroke to 32 mm and 50 mm.
  • Pencil heads: GT2-PA12, GT2-PA12K, GT2-PA12L and GT2-PA12KL, plus the short-range differential-transformer heads GT2-S1 at 1 mm and GT2-S5 at 5 mm.
  • Air-push heads GT2-A12, GT2-A12K, GT2-A12L, GT2-A32 and GT2-A50 are listed for applications where the spindle is driven by air rather than spring force.

What accuracy do the GT2 heads actually achieve?

The two GT2 sensing principles produce very different accuracy figures: the Scale Shot heads such as GT2-H12 quote 0.5 µm resolution and 2 µm p-p indicated accuracy over a 12 mm range, while the differential-transformer GT2-S5 quotes 0.1 µm resolution and 1 µm p-p accuracy over 5 mm with ±0.15% of full-scale linearity.

  • GT2-H12: absolute Scale Shot system with no tracking error, 1 ms sampling cycle, 10 Hz mechanical response at 20 °C, IP67, about 95 g without cable.
  • GT2-S5: 5 mm measuring range with a 7 mm operating spindle range, 1 ms sampling, 20 Hz mechanical response, IP67G when the M8 oil-resistant cable is used, SUS430F body, about 40 g.
  • The longer-stroke heads keep the same electronics but change the mechanism, which is why stroke should be selected from the fixture travel rather than from the resolution figure.

What does a GT2 amplifier add to the head?

The amplifier supplies the head and turns its position into judgement outputs: GT2-71P offers five PNP outputs at HH, HI, GO, LO and LL levels, a 0.1 µm display resolution across a ±199.9999 display range, and selectable response from 3 ms up to 1,000 ms. Without an amplifier the head has no output at all.

  • GT2-71P: DIN-rail main unit, 10 to 30 VDC supply, 2,200 mW or less, timing/preset/reset/bank no-voltage inputs, about 140 g including the power cable.
  • The GT2 group separates main and expansion units, analog and pulse variants, and panel-mount versions: GT2-71N/71P are DIN-rail mains with GT2-72N/72P as their expansions, GT2-71CN/71CP add analog output with GT2-72CN/72CP as expansions, GT2-71D carries a differential line-driver pulse output, and GT2-75N/75P with GT2-76N/76P are the panel-mount main and expansion pair.
  • Multi-head configurations use GT2-500 as the DIN-rail main unit and GT2-550 as the expansion unit, while GT2-E3N and GT2-E3P are expansion boards that fit the GT2-100N and GT2-100P large-display amplifiers.

How does the IL laser displacement family work?

IL is a two-part system as well: a passive CMOS laser head with no output of its own, and a DIN-rail or panel amplifier that supplies it and provides analog or judgement outputs. IL-1000 and IL-1500 are mains with analog outputs and IL-1050 and IL-1550 are their expansion units.

  • IL-030 head: 30 mm reference distance, 20 to 45 mm measurement range, 655 nm Class 1 laser at 220 µW, spot about 200 x 750 µm, sampling selectable at 0.33, 1, 2 or 5 ms, IP67, about 60 g.
  • IL-065 head: 65 mm reference distance, 55 to 105 mm measurement range, 655 nm Class 2 laser at 560 µW, spot about 550 x 1,750 µm, 2 µm repeatability, IP67, about 75 g.
  • Longer-range heads IL-100, IL-300 and IL-600, and the compact IL-S025 and IL-S065, share the same amplifier ecosystem, and the LK-G group adds one further laser displacement listing to the catalogue.

Which IL head suits which range and target?

Match the head to the working distance first: IL-S025 and IL-030 cover the short-range, high-accuracy end, IL-065 and IL-100 cover mid-range work, and IL-300 and IL-600 extend to longer standoff distances. Spot size grows with the range, so a small feature needs the shortest head that still clears the fixture.

  • Repeatability is quoted per head, not per family: 1 µm on IL-030 at 1 ms sampling against 2 µm on IL-065, both on a standard white diffuse target.
  • Linearity is specified over a partial span in the records: ±0.1% of full scale from 25 to 35 mm on IL-030 and from 55 to 75 mm on IL-065, so the usable measuring window is narrower than the quoted range.
  • Laser class changes with the head: IL-030 is Class 1 at 220 µW while IL-065 is Class 2 at 560 µW, which affects the laser safety assessment for the cell.

When should the older GT series be kept?

The GT series is the earlier contact generation: 14 listings built around GT-H, GT-A and GT-71/72/75/76 amplifiers, with 10 mm and 22 mm strokes and the same DIN-rail and panel-mount distinction. It remains the practical choice where an existing GT installation is being maintained rather than redesigned.

  • GT heads: GT-H10, GT-H22, GT-H10L, GT-H22L for standard and low-stress box types, plus GT-A10 and GT-A22 for air push.
  • GT amplifiers: GT-71A and GT-72A DIN-rail main and expansion, GT-75A and GT-76A panel main and expansion, with P versions adding PNP output in place of NPN.
  • Stroke and amplifier form factor are the only two decisions in the GT range, since every listing shares the general-purpose digital contact sensing principle.

Frequently asked questions

Can a GT2 head be used without a GT2 amplifier?

No. The GT2 heads are passive sensor heads that connect to a GT2 amplifier by M8 connector and take their supply from it, which is why the head records list supply voltage as not applicable. The amplifier provides the display, the judgement outputs and the timing inputs, so a working system always pairs one head family with one amplifier family.

What is the difference between GT2-H12 and GT2-H12K?

Both are 12 mm box-type heads, but the K suffix marks the high-precision version and L marks the low-stress version, with KL combining both. Select K when the measurement tolerance is tight, L when the part is soft or easily marked by the spindle, and the plain GT2-H12 when standard accuracy and standard measuring force are acceptable.

Does the GT2-S5 measure further than 5 mm?

The measuring range is 5 mm, but the record quotes a 7 mm operating range for the actual movable spindle travel, so the extra 2 mm is mechanical overtravel rather than usable measurement span. The linearity figure of ±0.15% of full scale applies to the 5 mm measuring range, and the 1 µm indicated accuracy is quoted p-p.

How fast can a GT2 measurement be sampled?

The head samples every 1 ms and the GT2-H12 record quotes a 10 Hz mechanical response at 20 °C, while GT2-S5 quotes 20 Hz. The amplifier response is set separately, from 3 ms in hsp mode up to 1,000 ms on GT2-71P, so the achievable cycle depends on both the head mechanics and the amplifier filter setting.

Why does the IL-065 have a larger spot than the IL-030?

Spot size scales with the optical design and working distance: about 200 x 750 µm at the 30 mm reference distance on IL-030 against about 550 x 1,750 µm at the 65 mm reference distance on IL-065. A larger spot averages over more surface, which is helpful on rough material and unhelpful on fine edges, so the shorter head is the better choice for small features.

Are IL heads and amplifiers sold as matching pairs?

They are listed separately and mix within the family. IL-1000 and IL-1500 are main amplifiers with analog outputs, IL-1050 and IL-1550 are expansion units without analog output, and any IL head in the group connects to them. The head determines range, spot and laser class, while the amplifier determines output format and channel count.

What protection rating do the contact heads carry?

GT2-H12 is quoted at IP67, and GT2-S5 at IP67G plus IP67 when the M8 oil-resistant cable GT2-CHP2M, CHP5M or CHP10M is used, with oil resistance coming from the cable rather than the head alone. Where coolant or oil mist is present, the cable part number is therefore part of the sealing specification.

Can GT2 measure a moving part?

It can, within the mechanical limits of the spindle. The head samples at 1 ms and GT2-H12 has a 10 Hz mechanical response, so a cam or a slow press stroke is measurable while a high-speed transfer is not. For fast-moving or delicate targets, the non-contact IL heads with 0.33 ms sampling are the appropriate alternative in this group.