FANUC spares split into two families here: A06B servo and spindle amplifiers, and A02B operator and control units. The recurring pitfall is that near-identical A06B drives differ in current rating and internal PWM stage, and A02B control units differ in communication and power — a visual match is not a functional match.
What these units are
- A06B-60xx — AC servo / spindle amplifiers. Input typically 200/220/230 V AC (±10/−15);
operating temperature 0–55 °C for servo amps, 0–40 °C for some spindle drives; many weigh ~19 lb (8.62 kg). - A06B-0186 — IP67 unit, rated power ~3.8 kW.
- A02B-0xxx — operator/control units. Inputs span 24 V DC to 100–240 V AC; several carry
Modbus or CS31 communication; LCD operator units use 100–240 V AC.
Model cross-reference (20 models)
| Model | Type | Key rating (published) |
|---|---|---|
| A06B-6066-H004 | AC servo amplifier | 200/220/230 V AC; 0–55 °C |
| A06B-6066-H003 | AC servo amplifier | — |
| A06B-6058-H224 | Servo/spindle drive | — |
| A06B-6058-H005 | Drive | Power rating 3.08 kW, PWM |
| A06B-6050-H104 | Drive | ~19 lb (8.62 kg) |
| A06B-6050-H102 | Drive | ~19 lb (8.62 kg) |
| A06B-6047-H040 | Drive | ~19 lb (8.62 kg) |
| A06B-6047-H004 | Drive | — |
| A06B-6047-H003 | Drive | — |
| A06B-0186-B675 | IP67 unit | Rated power 3.8 kW |
| A06B-0064-B203 | Drive | — |
| A02B-0307-B822 | Control unit | 24 V input |
| A02B-0285-B801 | Control unit | 100–240 V AC; 30 W; Modbus |
| A02B-0281-C081 | Control unit | 10.4″ LCD 800×600; 100–240 V AC |
| A02B-0281-C071 | Control unit | — |
| A02B-0281-B502 | Control unit | — |
| A02B-0259-B501 | Control unit | 100–240 V AC; 100 W |
| A02B-0211-B501 | Control unit | Modbus; 0–50 °C |
| A02B-0200-C081 | Control unit | 24 V DC; 0–50 °C |
| A02B-0118-B003 | Control unit | — |
Reading the FANUC ordering code
A06B-6066-H004: A06B = servo/spindle family; 6066 = design series;
H004 = variant (current/power stage). For A02B, the middle digits denote the control generation and
the suffix the I/O or display variant. Match the full code, not just the family.
Common sourcing mistakes
- Current/power-stage swap. Same family, different H-code — may be under/over-rated.
- Communication mismatch on A02B. Modbus vs other buses; confirm before fitting.
- Ignoring weight/power for cabling. 19 lb drives need rated mounting and cooling.
Condition reality: new, surplus, and refurbished
Industrial spares circulate in three conditions, and the label changes the risk profile:
- New / factory-sealed — lowest risk, highest price; verify the seal and date code.
- Surplus (new-unused, pulled from decommissioned lines) — often the best value; confirm it was stored dry and static-safe.
- Refurbished / tested — acceptable only with a functional test report; ask what was tested and to what standard.
For any electronic or power module, insist on a test report before payment. Appearance alone does not prove function, and a failed module on a live line costs far more than the saving.
Frequently asked questions
Can I swap a close A06B relative?
Only after confirming the full H-code; current/power stage must match.
Do A02B control units share power specs?
No — some are 24 V DC, others 100–240 V AC; check the label.
How do I confirm condition?
Request a functional test report; refurbished units should include test records.
This guide merges the individual model pages we previously published into one reference. The old per-model pages now redirect here. If you arrived from a specific model link, use the model list and ordering-code section below to land on the right part.