Skip to content

Fast quotes for industrial automation spare parts — send your model list today.

Keyence PZ-G, LR-Z, LR-W, LV-N and FS-N40 Sensor Selection Guide

Robotic arm stacking cartons on a roller conveyor, with a sensor mounted on the conveyor frame and AGVs in the background

Keyence photoelectric sensing is not one product line but four different answers to the same question: how much light has to come back, and how small is the target. The SpareTechHub catalogue lists 123 Keyence sensor listings in this group — 56 PZ-G self-contained photoelectric sensors, 18 LR-Z laser sensors, 6 LR-W colour sensors, 1 LR-T time-of-flight sensor, 30 LV-N laser amplifier items and 12 FS-N40 fibre amplifier items. This guide maps each family to the target and environment it handles, using the specifications held on the individual product records.

This page sits inside the wider Keyence buying guide, where the vision, safety, measurement and controller families are indexed by part-number prefix.

Which sensing principle should I start from?

Start with the beam path: thrubeam sensors need an emitter and receiver facing each other across the gap and give the most reliable detection at long range, diffuse sensors read light reflected from the target and need one mounting point, and retro-reflective sensors bounce the beam back from a reflector.

  • PZ-G51CP is a thrubeam with a 20 m maximum detecting distance; the diffuse PZ-G41CP reaches 1 m on 30 x 30 cm white paper; the retro-reflective PZ-G62CP works 0.1 to 1 m with an R-2L reflector.
  • All three PZ-G records quote a 500 µs maximum response time, 10 to 30 VDC supply, PNP open collector output rated 30 V 100 mA, IP67 with NEMA 4A/6/12 and DIN IP69K protection, and -20 to +55 °C operating temperature.
  • Browse the PZ-G series for all 56 self-contained models before deciding between beam types.

What does the PZ-G range actually cover?

PZ-G is a rectangular, self-contained family built around one 500 µs platform: the same 10 to 30 VDC supply, M8 connector, glass-fibre reinforced PBT housing and IP69K rating run across thrubeam, retro-reflective and diffuse versions, so the beam type and detecting distance are the only variables the application engineer has to settle.

  • Detecting distance separates the models by a factor of twenty: 20 m on the thrubeam PZ-G51CP, 1 m on the long-range diffuse PZ-G41CP and 0.1 to 1 m on the transparent-object PZ-G62CP with its reflector.
  • Current consumption follows the beam type — 20 mA for the PZ-G51CP transmitter and 28 mA for its receiver, against 34 mA for each of the single-housing diffuse and retro-reflective models.
  • Every PZ-G record lists the same mounting torque of 0.5 N·m and the same interference limit of two units using polarization filters or the automatic different frequency function.

When does a laser sensor replace an LED photoelectric sensor?

A laser sensor is the right move when the target is small, the background is close behind it or distance has to be measured rather than detected. The LR-Z family combines a visible 660 nm spot with distance and contrast detection, so it holds a switching point against a changing background.

  • LR-ZB100CP: 35 to 100 mm detecting distance, standard detectable deviation 1.5 mm from 35 to 50 mm and 3 mm from 50 to 100 mm, spot about 2 x 1 mm at 100 mm, Class 1 laser to IEC 60825-1.
  • Range steps in the family are set by the model: LR-ZB250AN covers 35 to 250 mm and LR-ZH500N covers 35 to 500 mm, all with the same 1.5 ms, 10 ms and 50 ms selectable response times.
  • The LR-ZB100CP record lists IP68, IP69K and NEMA 4X/6P/13 protection with an M8 four-pin connector, and IO-Link v1.1 COM2 on the CB and C3P connector variants.
  • The single LR-TB2000 listing extends the principle to time-of-flight measurement with a detection distance up to 2 m and a Class 2 red laser.

What handles transparent, shiny and colour targets?

Transparent objects need a retro-reflective sensor that detects the loss of the return beam, while colour differences need a sensor that reads the spectrum rather than the intensity. PZ-G62CP covers the first case with an infrared retro-reflective beam, and LR-W500 covers the second with a white LED and a 3.5 to 18 mm adjustable spot.

  • PZ-G62CP detecting distance is 0.1 to 1 m when the R-2L reflector is used, with a 500 µs response and the same PNP open collector output as the rest of the PZ-G range.
  • LR-W500: 30 to 500 mm detecting distance, white LED light source, response time selectable from 200 µs to 500 ms, NPN or PNP open collector output, IP65/IP67, about 170 g including cable.
  • The LR-W group holds six listings: the cable and M12 connector versions of the standard and small dual-spot models plus the fibre type LR-WF10, which moves the sensing point away from the amplifier.

Why use a separate amplifier and sensor head?

Separate amplifiers put the electronics on a DIN rail and the optics in a space too small for a self-contained sensor, and they add expansion plus fine response control. The LV-N laser amplifier reaches 80 µs in high-speed mode and accepts up to 17 units, while the FS-N40 fibre amplifier reaches 23 µs and takes 16.

  • LV-N11N: two control outputs, one external input, timer from 1 ms to 9,999 ms, response 80 µs to 16 ms across six modes, 24 VDC nominal, NPN open collector, 32.6 x 9.8 x 78.7 mm.
  • LV-NH37 is a diffuse-reflective spot head for the LV-N amplifier with a 70 ±15 mm detecting distance in MEGA mode and a Class 1 660 nm laser; the LV-N group holds 30 head and amplifier listings in total.
  • FS-N41P: PNP main unit, response 23 µs in S-HSPD mode through to 64 ms in TERA, red four-element 660 nm LED, 10 to 30 VDC, 100 mA per output, 16-unit expansion.

How do response times compare across the families?

Response time spans three orders of magnitude here: 23 µs on the FS-N41P fibre amplifier, 80 µs on the LV-N11N laser amplifier, 200 µs on the LR-W500 colour sensor and 500 µs on the PZ-G photoelectric range, while the LR-Z laser sensor offers 1.5 ms as its fastest setting.

  • Each record states its response as a maximum or a selectable set: 500 µs maximum on PZ-G51CP, 1.5/10/50 ms on LR-ZB100CP, 200 µs to 500 ms on LR-W500, and 80 µs to 16 ms across six modes on LV-N11N.
  • Faster settings usually trade against stability and cable length, and the LV-N11N record lists a 1 ms to 9,999 ms timer with ±10% maximum error for cases where the output has to be stretched rather than sped up.
  • The FS-N41P record also quotes 16 units of expansion with a derating note for operating temperature, which matters when a rail is filled with amplifiers in a sealed cabinet.

What wiring and environment details decide the order?

The connector, output type and ingress rating are model-level choices, not family defaults: PZ-G uses an M8 connector with PNP open collector output, LR-Z adds IO-Link on its CB and C3P variants, LR-W switches between NPN and PNP on the same part, and the amplifier families are split into separate NPN and PNP model numbers.

  • PZ-G records list IP67 with NEMA 4A/6/12 and DIN IP69K; LR-ZB100CP lists IP68, IP69K and NEMA 4X/6P/13; LR-W500 lists IP65/IP67; the LV-N11N and FS-N41P records do not quote an ingress rating at all.
  • Supply tolerance is consistent at 10 to 30 VDC on PZ-G, LR-Z, LR-W and FS-N41P, while LV-N11N is quoted as 24 VDC nominal with a 10 to 30 VDC operating window and 830 mW maximum consumption.
  • Ambient temperature separates the ranges: -20 to +55 °C on PZ-G and LV-N11N, -10 to +50 °C on LR-ZB100CP, -20 to +50 °C on LR-W500 and -20 to +55 °C on FS-N41P.

Frequently asked questions

Can one PZ-G model replace both a thrubeam and a diffuse sensor?

No. The PZ-G range shares a housing style and a 500 µs response, but the beam type is fixed per model and the detecting distance differs by an order of magnitude: 20 m on the thrubeam PZ-G51CP against 1 m on the long-range diffuse PZ-G41CP. A thrubeam also requires an emitter and receiver on opposite sides of the gap, while a diffuse model needs only one mounting position.

Is the LR-Z a measuring sensor or a switching sensor?

It is a switching sensor that uses distance information. The LR-ZB100CP record describes a self-contained CMOS laser photoelectric sensor with distance and contrast detection, quotes a standard detectable deviation of 1.5 mm to 3 mm, and lists a switching output rather than an analogue value. It is used to hold a stable switching point against a background, not to report a continuous measurement.

Which Keyence sensor is best for clear bottles and film?

The retro-reflective PZ-G62CP is the model explicitly listed for transparent object detection, working 0.1 to 1 m with an R-2L reflector, and it relies on the drop in returned light when the transparent target interrupts the beam. If the container also has to be identified by colour or printed contrast, the LR-W500 white LED colour sensor is the alternative in this group.

Does the LR-W500 come in separate NPN and PNP models?

No: the LR-W500 record states that the output is NPN or PNP open collector selectable, with a 30 VDC and 50 mA rating and N.O./N.C. selectable operation. That is different from the amplifier families, where LV-N11N is a fixed NPN model and FS-N41P is a fixed PNP model, so those two require the correct output version at order stage.

How many amplifiers fit on one DIN rail?

The LV-N11N record allows up to 17 units in total, counting a two-output type as two units, while the FS-N41P record allows 16 units of expansion, giving 17 including the main unit and counting a dual-output unit as two. Both records note that operating temperature derates as units are added, so the cabinet thermal calculation has to include the whole rail.

What is the smallest detectable spot in the range?

The LV-NH37 laser head is the spot-type option, with a 70 ±15 mm detecting distance in MEGA mode and a Class 1 660 nm beam, which is the configuration to use when the target is a fine feature rather than a whole part. For larger targets, the LR-W500 spot is adjustable from about 3.5 mm at 100 mm to 9 mm at 250 mm and 18 mm at 500 mm.

Do these sensors need a separate amplifier unit?

Only the LV-N and FS-N40 families. PZ-G, LR-Z, LR-W and LR-T are self-contained sensors with the output transistor inside the housing, so they connect straight to the PLC input or relay. LV-N11N and FS-N41P are amplifiers that require a matching head or fibre unit, which is why the catalogue lists heads such as LV-NH37 separately.

Which models are rated for washdown?

PZ-G records list DIN IP69K alongside IP67 and NEMA 4A/6/12, and LR-ZB100CP lists IP68 with IP69K plus NEMA 4X/6P/13, so those two families are the ones with a published high-pressure washdown rating. LR-W500 is quoted at IP65/IP67, while the LV-N11N and FS-N41P records carry no ingress rating, so they belong inside an enclosure.