The Allen-Bradley Bulletin 150 SMC-Flex is a solid-state soft starter. Selection turns on three numbers: rated current, HP at the supply voltage, and input voltage class. A 150-F135 and a 150-F108 are different current classes entirely, and the input voltage (200-460 vs 500-575) must match the supply.
What these units are
All are Allen-Bradley Bulletin 150 SMC-Flex solid-state controllers. Rated voltages observed across the
range include 230 V, 400/415/460 V, 500/575 V and 690 V classes; control power is typically 100–240 V AC.
The F1xx digits denote the current class.
Model cross-reference (20 models)
| Model | Current class | Key rating (published) |
|---|---|---|
| 150-F135FCD | 135 A | 100 Hp @ 460 V; 500–575 V AC; IP65 |
| 150-F135FBD | 135 A | 400/415/460 V class |
| 150-F135FAD | 135 A | 230 V class |
| 150-F1250NZE | 1250 class | see nameplate |
| 150-F1250NZA | 1250 class | see nameplate |
| 150-F1250NCE | 1250 class | 500/575 V (delta) |
| 150-F1250NCA | 1250 class | 500/575 V; −5…50 °C |
| 150-F1250NBED | 1250 class | see nameplate |
| 150-F1250NBE | 1250 class | 200–460 V |
| 150-F1250NBA | 1250 class | see nameplate |
| 150-F108NZD | 108 A | 690 V class |
| 150-F108NCR | 108 A | see nameplate |
| 150-F108NBRB | 108 A | see nameplate |
| 150-F108NBR | 108 A | see nameplate |
| 150-F108NBDB | 108 A | 108 A / 75 Hp @ 460 V; 200–460 V AC |
| 150-F108FHD | 108 A | 200–208 V AC |
| 150-F108FCD | 108 A | see nameplate |
| 150-F108FBD | 108 A | 200–460 V AC; 75 Hp class |
Reading the 150 ordering code
150-F135FCD: 150 = Bulletin; F135 = current class (135 A); F = frame;
CD = voltage/option. Match the current class and the input-voltage class to the supply before ordering.
Common sourcing mistakes
- Current class confusion. F135 (135 A) vs F108 (108 A) are not interchangeable.
- Input voltage. 200–460 V units will not suit a 500–575 V supply and vice versa.
- HP at voltage. HP rating is voltage-dependent; confirm at your supply voltage.
Condition reality: new, surplus, and refurbished
Industrial spares circulate in three conditions, and the label changes the risk profile:
- New / factory-sealed — lowest risk, highest price; verify the seal and date code.
- Surplus (new-unused, pulled from decommissioned lines) — often the best value; confirm it was stored dry and static-safe.
- Refurbished / tested — acceptable only with a functional test report; ask what was tested and to what standard.
For any electronic or power module, insist on a test report before payment. Appearance alone does not prove function, and a failed module on a live line costs far more than the saving.
Frequently asked questions
Are 150-F135 and 150-F108 the same?
No — different current classes (135 A vs 108 A).
Does input voltage matter?
Yes — 200–460 V vs 500–575 V must match the supply.
How do I confirm condition?
Request a functional test report; refurbished units should include test records.