A PROFINET upgrade no longer requires an outage. With Fragmentation — defined in specification V2.3 — PROFINET realizes cycle times down to 31.25 µs while standard TCP/IP traffic still runs on the same cable. The hard part is not bandwidth; it is cutting over one island at a time without stopping the line.

What should a network map include?
The first deliverable of any upgrade is an honest inventory: every protocol in use, every node address, every media converter, and every undocumented repeater hiding above the cable tray. Half of upgrade risk lives in devices nobody remembered. A map also reveals which segments genuinely need upgrade now and which are stable candidates for a later phase, which shortens the project and shrinks the risk surface.
How do you cut over without an outage?
Wherever the architecture allows, run the new network alongside the old one. Dual-homed devices, secondary switch rings, and pre-staged patching mean the cutover becomes a connector move, not a construction project. When a full parallel run is not practical, cut over by cell or by line section: one functional island at a time, each validated before the next moves.
Two standards bodies make the parallel-run pattern durable rather than clever. PI’s PROFINET specification (V2.3 and later) adds Fast Forwarding, Dynamic Frame Packing and Fragmentation, so real-time traffic and normal TCP/IP coexist on one cable with cycle times down to 31.25 µs (PROFINET technology). And ODVA describes EtherNet/IP as running “on standard, unmodified Ethernet” with topologies including “star, linear, and device level ring (DLR)” (ODVA) — meaning a second network can share the infrastructure you already own instead of demanding a parallel cable plant.

Can legacy devices join a new network without replacement?
Protocol gateways let legacy devices participate in a new network without replacement, buying years of life for hardware that is expensive to swap. They are also useful as a permanent pattern for isolating older segments from modern traffic. The discipline is documenting exactly which translations the gateway performs, so the mapping is knowledge on paper rather than in one engineer’s head.
A concrete example from our own stock: the Schneider Quantum 140CRA93200, an S908 remote I/O slave with two connectors for redundant cable — exactly the class of legacy hardware a gateway keeps alive on a new network instead of forcing a rewiring project.
How do you roll back a failed cutover?
Every cutover step needs a written way back: the old configuration saved, the previous physical path preserved until validation passes, and a time limit after which the decision to roll back is automatic rather than argued. Teams that know they can retreat cut over faster, because hesitation is usually fear of the irreversible step. Remove irreversibility and the schedule holds.
| Phase | Deliverable | Fallback |
|---|---|---|
| 1 · Map | Protocol list, node addresses, undocumented repeaters | Nothing is touched |
| 2 · Parallel run | Dual-homed devices, pre-staged patching — cutover becomes a connector move | Plug the old cable back in |
| 3 · Gateway | Translation mapping written down (which traffic is translated into what) | Legacy segment stays physically isolated |
| 4 · Cutover | One functional island at a time, each validated before the next | Config saved, old path preserved, timeout triggers automatic rollback |
Between phases, spare network hardware, media converters, and interface modules should sit on your shelf alongside the PLC spares, because the same physics applies: everything with a port eventually fails. If you need current-production or legacy network modules for a staged upgrade, tell us the device list and we will match the hardware to your plan.
Frequently asked questions
What is the shortest PROFINET cycle time?
31.25 µs, realized with Fragmentation as defined in the PROFINET specification V2.3 and later, with standard TCP/IP traffic transferred in parallel.
Can legacy devices join a new industrial network without replacement?
Yes, through protocol gateways — but document exactly which translations the gateway performs so the mapping outlives the engineer who set it up.
How do you roll back a failed network cutover?
Saved configuration, preserved physical path, and a time limit after which rolling back is automatic rather than argued.
Bottom line
Sequence the network upgrade around the changeover window and the line keeps producing; the hardware is the easy part once the ordering is right.